Figure 17
Legend:
1
NTC domestic hot water sensor
2
Boiler drain tap
3
Boiler filling tap
4
Water pressure switch
5
Gas valve
6
Gas train with injectors
7
Water-fumes exchanger
8
Fumes conveyor
9
Fan
10
Positive pressure point
11
Negative pressure point
INSTRUCTIONS FOR FITTERS
29. FUNCTIONAL CIRCUIT DIAGRAM
Heating
DHW
delivery
outlet
24 F
Gas
DHW
Heating
inlet
return
12
Air pressure switch
13
Central heating NTC sensor
14
Safety thermostat
15
Ignition / flame detection electrode
16
Burner
17
Expansion vessel
18
Pump and air separator
19
Pressure gauge
20
Safety valve
21
Automatic by-pass
22
DHW priority sensor
47
71.07144.01 - EN