Configuring The Clocking Scheme - Nortel Passport 241-5101-200 Installation Manual

Nortel networks ethernet switching installation guide
Table of Contents

Advertisement

40 Chapter 4 Configuring the Passport 8250 for operations
4
5
6
7
8
Configuring the clocking scheme
To configure the clocking scheme for the Passport 8250 device, select the
source for the reference clock, and, if applicable, select the switching option
using the clockconfig command.
The switching methods are the following:
The syntax of the clockconfig command is:
241-5101-200 R2.2
For host inet, type the IP address of the remote host.
If the remote host is on a different network, type the IP address of the
gateway node at the gateway inet prompt.
For user, type the FTP userid of the remote host.
For ftp password, type the FTP password of the remote host.
Reboot the Passport 8250 device to save the boot parameters.
reboot
Note:
After restarting the Passport 8250, you can log into the CLI only
after ****BOOT COMPLETE, SYSTEM IS READY**** is displayed.
Internal. The clocking scheme is derived from the Passport 8250 device.
External. The clocking scheme is derived from the ATM network off the
ATM uplink port or a T1/E1 port on the Passport 8250. Select one of the
following switching options:
— Fixed. The clocking scheme is fixed permanently to the primary
port. If there is a problem with the primary port, you need to change
to the secondary port using the clockconfig command.
— Automatic switching. The clocking scheme is temporarily fixed to
the primary port. The Passport 8250 automatically switches from the
primary port to the secondary port and, if needed, switches from the
secondary port to internal.
Note: We recommend that you select the device with the lower stratum
clock as the clock source. The Passport 8250 has a stratum 4 clock.
clockconfig [set]