VS-GSLG OPERATOR INSTALLATION GUIDE
VS-GSLG OPERATOR INSTALLATION GUIDE
VS-GSLG OPERATOR INSTALLATION GUIDE
VS-GSLG OPERATOR INSTALLATION GUIDE
VS-GSLG OPERATOR INSTALLATION GUIDE
TERMINALS
FUNCTION
24VAC
24VAC
24VAC N
24VDC+
24VDC
24VDC- COMM.
1 & 4
OPEN
3 & 4
CLOSE
4 & 5
SINGLE-BUTTON
2 & 4
STOP
4 & 6
REVERSE
4 & 50
OPEN
OBSTRUCTION
4 & 51
CLOSE
OBSTRUCTION
4 & 11
SHADOW/HOLD
24VDC+ & 60
RUN/PRE-START
You must follow all required safety precautions and instructions at all times. Review the safety brochure
included with the operator. If any pages are missing or unreadable, contact OSCO at 1-800-333-1717 to request
additional copies.
Never connect a button station within reach of the gate or on the side of the gate operator.
Do not adjust the circuit board current sensing feature too high. It should be adjusted high enough to keep the
gate from falsely triggering the sensing, but no higher than necessary for the gate to operate. Do not defeat the
purpose of this function!

TERMINAL CONNECTION DESCRIPTIONS

TERMINAL CONNECTION DESCRIPTIONS
TERMINAL CONNECTION DESCRIPTIONS
TERMINAL CONNECTION DESCRIPTIONS
TERMINAL CONNECTION DESCRIPTIONS
DESCRIPTION OF FUNCTION
Provides 24Volt AC power for accessories.
Note: DC models will NOT have 24Volt AC power available.
Provides 24Volt DC power for accessories.
Opens the operator. Several accessories such as button stations, keypads, trans-
mitters and card readers can be wired to open.
Closes the operator. Use caution when wiring accessories to these terminals. The
gate must be clearly visible from the location of any accessories wired to
close.
Performs the single-button function which will alternate between open and close or
open, stop and close - depending on dip switch #3. (See page 10 for details.)
Stops the operator. If no stop button is used, a jumper is required across 2&4.
This function will cause a reversal when the gate is traveling closed and will travel
back to the fully open position. Loop detectors are often wired for reverse.
This function works only while the operator is opening. Any signal to this function
will cause the gate to stop, reverse a short distance, and then stop again. At this
time the auto close timer is disabled, and a renewed input will be required to start
the gate again. Should the gate be restarted and the signal occur again prior to
reaching a limit, the gate will stop again, and this time will sound the emergency
alarm and lock out.
This function works exactly like the OPEN OBSTRUCTION, except that it will only
work in the closing direction.
This function will keep the gate in its fully open position while the signal is present.
This is typically used with a loop and loop detector to keep a large swing gate open
while vehicular traffic is passing through.
A 24Volt DC device such as a strobe light or alarm can be wired to these terminals.
Depending on dip switch #2, these devices will either begin three seconds before
the operator starts, or only while the motor is running. (See page 10 for details.)
- 11 -
- 11 -
- 11 -
- 11 -
- 11 -
12-04-11