When connected with the Micom, the display message on
the Output window appears as below.
Connecting to MPLAB ICD 2
...Connected
Setting Vdd source to MPLAB ICD 2
Target Device PIC18F242 found, revision = 0x7
...Reading ICD Product ID
Running ICD Self Test
...Passed
MPLAB ICD 2 Ready
(5) Select "File -> Import", select the Work HEX file and open.
(6) Select "Programmer -> Program".
(7) Download begins and about 3 seconds later, the
"Programming succeeded" message is displayed on the
Output window and the Download process is ended.
Note: Step (6) is more convenient when using the short-cut icon.
ADJUSTMENT INSTRUCTIONS
11. POD Certificate Download &
IEEE1394(DTCP) Download
11-1. Preparation for Adjustment
(1) Connect the MEMORY JIG and PC.
(2) Turn on the JIG MAIN POWER SWITCH.
(3) After turning on the PC and MONITOR, execute the
'Certificate Downloader v1.4' from the screen.
11-2. Adjustment Sequence
(1) After opening the 'Certificate Downloader v1.4', enter
Connection set and set the as same below.
The port settings are determined by each PC's setup.
(2) Select 'Connection' and SET connected to RS-232C.
(3) After clicking "Enter", confirm that "Enter Password:"
appears.
(4) Click the "OpenFile - Download" button from CP Data
Download, 'select the Private Key' appears and click
ENTER.
- 13 -