LG DU-52SZ61D Service Manual page 12

Hide thumbs Also See for DU-52SZ61D:
Table of Contents

Advertisement

(5) Select "File -> Import", select the Work HEX file and open.
(6) Select "Programmer -> Program".
(7) Download begins and about 3 seconds later, the
"Programming succeeded" message is displayed on the
Output window and the Download process is ended.
Note: Step (6) is more convenient when using the short-cut icon.
10. Gemstar IR Micom Download
10-1. Preparation for Adjustment
(1) As shown below, connect the MPLAB ICD2 equipment, PC
and Digital Connector.
(2) Turn on the MPLAB ICD2 POWER Supply.
(3) After turning on the PC and MONITOR, select 'MPLAB
IDE' from the screen.
Connect the RS-232 or USB Cable
Connect the MPLAB ICD2 and connector of Digital Board
ADJUSTMENT INSTRUCTIONS
CN1203
+13V
+5V
IC1205
GND
IR Micom
Data
Clock
<Digital Board>
10-2. Adjustment Sequence
(1) When the program is executed, select MPLAB ICD2 from
"Programmer -> Select Programmer"
(2) Select "Configure -> Select Device".
(3) When the "Select Device" window appears, select
PIC18F242 from "Device" and press OK.
(4) Select "Programmer -> Connect".
- 12 -

Advertisement

Table of Contents
loading

Table of Contents