Electrical Adjustments
Item No.
NAME
47
NOR_VALU_FAN1_MAX
48
NOR_VALU_FAN2_MIN
49
NOR_VALU_FAN2_MAX
50
ECO_TEMP_FAN1_MIN
51
ECO_TEMP_FAN1_MAX
52
ECOTEMP_FAN2_MIN
53
ECO_TEMP_FAN2_MAX
54
ECO_VALU_FAN1_MIN
55
ECO_VALU_FAN1_MAX
56
ECO_VALU_FAN2_MIN
57
ECO_VALU_FAN2_MAX
58
HINOR_TEMP_FAN1_MIN
59
HINOR_TEMP_FAN1_MAX
60
HINOR_TEMP_FAN2_MIN
61
HINOR_TEMP_FAN2_MAX
62
HINOR_VALU_FAN1_MIN
63
HINOR_VALU_FAN1_MAX
64
HINOR_VALU_FAN2_MIN
65
HINOR_VALU_FAN2_MAX
66
HIECO_TEMP_FAN1_MIN
67
HIECO_TEMP_FAN1_MAX
68
HIECOTEMP_FAN2_MIN
69
HIECO_TEMP_FAN2_MAX
70
HIECO_VALU_FAN1_MIN
71
HIECO_VALU_FAN1_MAX
72
HIECO_VALU_FAN2_MIN
73
HIECO_VALU_FAN2_MAX
74
CLNOR_TEMP_FAN1_MIN
75
ClNOR_TEMP_FAN1_MAX
76
CLNOR_TEMP_FAN2_MIN
77
CLNOR_TEMP_FAN2_MAX
78
CLNOR_VALU_FAN1_MIN
79
CLNOR_VALU_FAN1_MAX
80
CLNOR_VALU_FAN2_MIN
81
CLNOR_VALU_FAN2_MAX
82
CLECO_TEMP_FAN1_MIN
83
CLECO_TEMP_FAN1_MAX
84
CLECOTEMP_FAN2_MIN
85
CLECO_TEMP_FAN2_MAX
86
CLECO_VALU_FAN1_MIN
87
CLECO_VALU_FAN1_MAX
88
CLECO_VALU_FAN2_MIN
89
CLECO_VALU_FAN2_MAX
90
FAN_1_AUTO_ADJ
91
FAN_2_AUTO_ADJ
92
FACTORY_STD_FAN_VOL_MIN
93
FACTORY_STD_FAN_VOL_MAX
94
FAN1_ADJUST_VOLT_MIN
95
FAN1_ADJUST_VOLT_MAX
96
FAN2_ADJUST_VOLT_MIN
97
FAN2_ADJUST_VOLT_MAX
TEMP_ERROR_DETECT_MAX_
98
TIMES
99
FAN_1_MIN_VOL_LAMP_DIFF
100
FAN_2_MIN_VOL_LAMP_DIFF
101
LAMP_VOL_BORDER_LINE
102
LAMP_VOL
103
Dimmer Voltage Change Cycle
104
Dimmer Avarage Check Period
105
Dimmer Voltage Change Rate
106
Dimmer Average
107
Last Voltage Difference
108
Voltage Difference Goal
109
OnStart_Cooling_Start_Temp
Group 200
Auto Calibration
0
Execute Calibration
1
Loop Count
2
OFFSET AREA H START
3
OFFSET AREA V START
4
GAIN AREA H START
5
GAIN AREA V START
6
Image AREA H WIDTH
7
Image AREA V HIGHT
8
OFFSET target
9
OFFSET torelance
10
GAIN target
11
GAIN torelance
12
Offset Area Average [ Red ]
13
Offset Area Average [ Green ]
14
Offset Area Average [ Blue ]
XGA
Device
Component
PC
HDTV
480p
M62398FP
135
M62398FP
73
M62398FP
113
PW185B
47
PW185B
51
PW185B
47
PW185B
51
PW185B
52
PW185B
115
PW185B
62
PW185B
85
PW185B
43
PW185B
43
PW185B
43
PW185B
43
M62398FP
135
M62398FP
135
M62398FP
119
M62398FP
119
PW185B
44
PW185B
44
PW185B
44
PW185B
44
M62398FP
120
M62398FP
120
M62398FP
91
M62398FP
91
PW185B
47
PW185B
50
PW185B
47
PW185B
50
M62398FP
68
M62398FP
135
M62398FP
73
M62398FP
113
PW185B
48
PW185B
51
PW185B
48
PW185B
51
M62398FP
52
M62398FP
115
M62398FP
62
M62398FP
85
PW185B
0
PW185B
0
PW185B
52
PW185B
135
M62398FP
15
M62398FP
203
M62398FP
15
M62398FP
203
5
0
0
70
-
3
10
1
-
-
-
PW185B
38
PW185B
0
PW185B
3
PW185B
25
PW185B
500
PW185B
975
PW185B
500
PW185B
13
PW185B
9
PW185B
1
PW185B
1
PW185B
244
PW185B
1
PW185B
0
PW185B
0
PW185B
0
Range Description
Video
480i
NTSC
PAL
FAN1 Control Max at Normal
0-255
FAN2 Control Min at Normal
FAN2 Control Max at Normal
FAN1 Control start temp.at Eco
FAN1 Control end temp. at Eco
0-255
FAN2 Control start temp.at Eco
FAN2 Control end temp. at Eco
FAN1 Control Min at Eco
FAN1 Control Max at Eco
0-255
FAN2 Control Min at Eco
FAN2 Control Max at Eco
FAN1 Control start temp.at Highland Normal
FAN1 Control end temp. at Highland Normal
0-255
FAN2 Control start temp.at Highland Normal
FAN2 Control end temp. at Highland Normal
FAN1 Control Min at Highland Nromal (0:0V, 255:25.5V)
FAN1 Control Max at Highland Normal
0-255
FAN2 Control Min at Highland Normal
FAN2 Control Max at Highland Normal
FAN1 Control start temp.at Highland Eco
FAN1 Control end temp. at Highland Eco
0-255
FAN2 Control start temp.at Highland Eco
FAN2 Control end temp. at Highland Eco
FAN1 Control Min at Highland Eco
FAN1 Control Max at Highland Eco
0-255
FAN2 Control Min at Highland Eco
FAN2 Control Max at Highland Eco
FAN1 Control start temp.at Ceiling Normal
FAN1 Control end temp. at Ceiling Normal
0-255
FAN2 Control start temp.at Ceiling Normal
FAN2 Control end temp. at Ceiling Normal
FAN1 Control Min at Ceiling Nromal (0:0V, 255:25.5V)
FAN1 Control Max at Ceiling Normal
0-255
FAN2 Control Min at Ceiling Normal
FAN2 Control Max at Ceiling Normal
FAN1 Control start temp.at Ceiling Eco
FAN1 Control end temp. at Ceiling Eco
0-255
FAN2 Control start temp.at Ceiling Eco
FAN2 Control end temp. at Ceiling Eco
FAN1 Control Min at Ceiling Eco
FAN1 Control Max at Ceiling Eco
0~255
FAN2 Control Min at Ceiling Eco
FAN2 Control Max at Ceiling Eco
0-1
0: OFF(Manual) 1:ON(Auto)
0-1
0: OFF(Manual) 1:ON(Auto)
0-255
For Factory
0-255
For Factory
For Factory
For Factory
0~255
For Factory
For Factory
1-9
Detecting times for Temp Error
0-20
0-20
30-90
0-255
Present Lamp Voltage
Change cycle of voltage at Dimmer
Measurement time of Dimmer average
Voltage change rate ta Dimmer
Dimmer average
Last voltage difference
Target voltage difference at Dimmer
0-100
0 - 255 Auto executiong when value changes
1 - 30
Loop times of Auto Calibration
0 - 4095 Black Level Acquire area H-Start Position
0 - 4095 Black Level Acquire area V-Start Position
0 - 4095 White Level Acquire area H-Start Position
0 - 4095 White Level Acquire area V-Start Position
0 - 4095 Black/White Level Acquire area
0 - 4095 Black/White Level Acquire area Height
0 - 127 Target for Black Level Adj.
1 - 127 Allowence Range for Black Level Adj
0 - 255 Target for White Level Adj.
1 - 255 Allowence Range for White Level Adj
0 - 255 Read Only