OPTIONAL BLOWER INSTALLATION
INSTALLATION TO BE DONE BY A QUALIFIED IN-
STALLER and must be electrically connected and grounded
in accordance with local codes. In the absence of local
codes, use the current CSA C22.1
Canada or the ANSI/NFPA 70
United States.
FIGURE 59
The three slots on
the blower mount-
ing bracket allow
ease of adjustment
when attaching the
blower. For a quiet
running blower, do
not allow the as-
sembly to sit on the
firebox base.
Slide the vibration reducing pad (A) into the clip (C) and up
against the threaded stud (B) at the other end. The blower
must be able to be positioned entirely onto the pad.
Tilt the blower onto its side. Slide it past the controls and
into the clip (C). Secure to the threaded stud using the lock
washer and wing nut provided. Ensure that the blower
does not touch the fireplace base or the firebox.
B
A
FIGURE 61
W415-0341 / K / 10.05.07
CANADIAN ELECTRICAL CODE
NATIONAL ELECTRICAL CODE
If the fireplace was not previ-
ously equipped with a blower:
route a grounded 2-wire, 60hz
power cable to the receptacle /
junction box. At this point, it must
be strain relieved and insulated.
FIGURE 60
FIGURE 62
in
in the
Attach the connectors from the black and white wires to the
thermodisc and secure the thermodisc bracket to the se-
curing stud at the bottom left of the unit using a lock washer
and wing nut. Ensure that the thermodisc touches the fire-
box wall.
Attach the connectors from the black and red wires to the
blower.
Attach and secure the variable speed switch using the nut
provided. Plug the harness cord into the receptacle.
The wire harness provided in this kit is a universal
harness. When installed, ensure that any excess
wire is contained, preventing it from making con-
tact with moving or hot objects.
Because the blower is thermally activated, when
turned on, it will automatically start approximately
10 minutes after lighting the fireplace and will run
for approximately 30-45 minutes after the fireplace
C
has been turned off. Use of the fan increases the
output of heat.
Drywall dust will penetrate into the blower bearing
causing irreparable damage and must be pre-
vented from coming into contact with the blower or
its compartment. Any damage resulting from this
condition is not covered by the warranty policy.
FIGURE 63
FIGURE 64