FLOW CHART NO.1
The power cannot be turned on.
Is the fuse normal?
Are Pins (1,2,5,8,9,11) on CN501 are shorted?
Is the +4.5V voltage outputted between Pin (11)
and GND?
After reconnecting CLN6 to CN501, does the
voltage between each pin and GND become
following value during turning the power on?
CN501 Pins (1,2) P-ON+6.5V
CN501 Pins (8,9) P-ON+21V
Is the +3.3V voltage outputted to the emitter of
Q503?
Is the "H" signal inputted into Pin (2) on CN502?
Replace the Plasma Display Module.
TROUBLESHOOTING
Yes
No
Yes
No
Yes
No
Yes
No
Yes
1-7-1
No
Remove CLN6 connecting to CN501 and check
Pins (1,2,5,8,9,11) on CLN6 are shorted.
Not shorted
After replacing fuse,
does it break when
turning the power on ?
No
Yes
Check each line of power supply on the Analog
CBA and service it if defective.
No
Replace the Plasma Display Module.
Check Q503, D503 and the periphery circuit,
and service it if defective.
Replace IC205.
Shorted
Yes
Replace the Plasma
Display Module.
L0605TR