Outdoor Use - Lochinvar Copper-Fin II CX401 Designer's Manual

Table of Contents

Advertisement

Lochinvar
(FIG. 2) MODELS CH 401-751 INSTALLED WITH
Outdoor models require the installation of
5.
an optional vent cap. Instructions for
placement of the vent cap are included in
the venting section.
CLEARANCES
Right Side
Rear
Left Side
Front
Top
Flue
Hot Water Pipes
* Alcove is a closet without a door.
+ Consult local codes and/or vent manufacturer.
4
L o c h i n v a r
OPTIONAL COMBUSTIBLE FLOOR BASE
(TABLE B) – CLEARANCES FROM COMBUSTIBLES
'
D E S I G N E R
S
G U I D E
Outdoor models must not be installed
directly on the ground. The outdoor unit
must be installed on a concrete brick,
block or other non-combustible pad.
Outdoor models have additional special
location and clearance requirements.
(See Outdoor Installation Pg. 16)
SPECIAL LOCATION:

OUTDOOR USE

Copper-Fin II Models are approved for
outdoor installations. Outdoor models have
additional location and clearance
requirements. These requirements must be
adhered to carefully, since wind, rain, snow
and cold cannot be controlled in outdoor
applications. See Outdoor Installation,
in the venting section on page 16.
CH401-751
1"
1"
6"
(24" for Service)
ALCOVE*
(24" for Service)
1"
1"+
1"
-
C O P P E R
F I N
I I
CH991-2071
3"
3"
3"
(24" for Service)
ALCOVE*
(30" for Service)
3"
1"+
1"
6 1 5 - 8 8 9 - 8 9 0 0
B O I L E R