WALL-VENTED INSTALLATION:

1. Remove one blower unit mounting screw and one blower
plate screw. Remove the blower plate from cabinet.
See Figure 13.
2. Carefully lift the blower unit out of the microwave oven.
3. Use side cutters or tin snips to cut and remove knockouts
"B" from Back plate. Discard knockouts. Be careful not
to distort the plate. See Figure 14.
4. Reassemble the blower wire. See Figure 15.
5. Rotate the unit so that the exhaust ports face the rear of
the cabinet. See Figure 16. When you insert blower unit,
blower wire must be like Figure 16.
6. Place blower unit back into cabinet. Check that the
exhaust ports face towards the rear of the cabinet.
See Figure 17.
7. Reattach the blower plate to cabinet so the exhaust ports
and blower plate opening are aligned. Attach with one
blower unit mounting screw and then one blower plate
mounting screw. See Figure 18.
Figure 15
STEP 3:
PREPARE THE VENTING BLOWER
blower unit
Parts "B"
Figure 13
Parts "B"
Figure 14
Figure 16
11
back plate
blower plate
mounting screws
blower unit
mounting screw
Knockout Parts "B"
blower
unit
exhaust
ports