Indoor Unit Installation
Wall Mounting
3.
Installation.
• Install the indoor unit on the wall according to the installation drawings.
1) Hang the indoor unit on the hooks of
2) Fix the three holes in the lower portion of the indoor unit with M4 × 25L screws.
J Side cover
(6 claws)
M4 × 25L
Front grille
Condition for installation
less than 1
• Work should be performed to match the direction of the piping, as the extension auxiliary pipe (
tion methods vary depending on the direction the piping is brought out.
1) Select the extension auxiliary pipe in accordance with the
direction of the piping. (This should be done without the
included piping for wall-mounted right-back piping and
ceiling-mounted upper right-side piping.)
2) Attach the heat insulation tube
iary pipe. (Make sure there are no gaps.)
3) Attach the extension auxiliary pipe to the product.
7
mounting plate. (2 places)
A
Electric component cover
(2 claws)
to the extension auxil-
N
A
Mounting plate
J Side cover
Indoor unit
hook portion
2)
A Mounting plate
, supplied) and installa-
M
3)
Bottom-
right piping
Right side
piping