Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
hestan Manuals
Ranges
HFT Series
Owner's manual
hestan HFT Series Owner's Manual
French top
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
page
of
11
Go
/
11
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Installation
Installation Procedure
Uncrating
Location
Clearances
Placing Appliance
Leveling
Section 1: Installation
Riser Installation
Statutory Regulations
United States of America
Canada
Gas Supply
Gas Pressure Regulator
Ventilation Air / Flue Connections
Electrical Supply
Model / Serial / Rating Plate Location
Operating Instructions
Lighting and Shutdown Instructions
Section 2: Operating Instructions
Cleaning and Maintenance
Gas-Fired Appliances
Service
Troubleshooting Guide
Advertisement
Quick Links
Download this manual
Owner's Guide
Installation & Operation
French Top
HFT Series
Hestan Commercial Corporation
3375 E. La Palma Ave
Anaheim, CA 92806
(888) 905-7463
RETAIN THIS MANUAL FOR FUTURE REFERENCE
P/N 002131 REV 1
1
©2015 Hestan Commercial Corporation
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Related Manuals for hestan HFT Series
Ranges hestan KRT365 Installation Instructions Manual
Gas conversion kit range/rangetop (16 pages)
Ranges hestan KRD365-NG Use & Care Manual
Krd series (104 pages)
Ranges hestan KRG Installation Manual
Indoor cooking all-gas range (48 pages)
Ranges hestan KRG Use & Care Manual
All-gas range (80 pages)
Ranges hestan KRDS Series Use & Care Manual
Dual-fuel range, dual-fuel smart range (132 pages)
Ranges hestan KRD485GDNG Installation Manual
Dual-fuel range (48 pages)
Ranges hestan KRD365LPYW Use & Care Manual
Dual-fuel range (104 pages)
Ranges hestan KRD485GDNGWH Use & Care Manual
Dual-fuel range (112 pages)
Ranges hestan KRG365NGYW Use & Care Manual
(76 pages)
Ranges hestan KRD304-LP Installation Manual
Dual-fuel range (48 pages)
Ranges hestan KRD Use & Care Manual
(132 pages)
Ranges hestan KRG365NGBU Use & Care Manual
All-gas range (76 pages)
Ranges hestan KRG Series Installation Manual
All-gas range (40 pages)
Ranges hestan KRD Series Installation Manual
Dual-fuel (36 pages)
Summary of Contents for hestan HFT Series
Page 1
Owner’s Guide Installation & Operation French Top HFT Series Hestan Commercial Corporation 3375 E. La Palma Ave Anaheim, CA 92806 (888) 905-7463 RETAIN THIS MANUAL FOR FUTURE REFERENCE P/N 002131 REV 1 ©2015 Hestan Commercial Corporation...
Page 2
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ INSTALLATION, OPERATING MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT. IN THE EVENT OF A POWER FAILURE, DO NOT ATTEMPT TO OPERATE THIS DEVICE. ©2015 Hestan Commercial Corporation...
Page 3: Table Of Contents
Electrical Supply .....................8 Model / Serial / Rating Plate Location ..............8 Section 2: Operating Instructions ................Lighting and Shutdown Instructions ..............9 Section 3: Cleaning and Maintenance ..............Gas-Fired Appliances ..................10 ....................Service Troubleshooting Guide .................. 11 ©2015 Hestan Commercial Corporation...
Page 4: Installation
4” legs are mounted using four hex-head bolts per leg and each leg is adjustable simply by turning the inner cylinder leg, clockwise to lower and counter-clockwise to elevate. NOTE: A carpenter’s level can be used on the plate shelf for left to right leveling. ©2015 Hestan Commercial Corporation...
Page 5: Riser Installation
National Fire Protection Association, on their web site: http://www.nfpa.org/ Canada 1) Local Codes 2) CSA B149.1 Natural Gas and Propane Installation Code. 3) CSA C22.1 Canadian Electrical Code 4) CSA C22.2 Canadian Electrical Code Canadian codes can be found on the CSA website: http://www.csa.ca ©2015 Hestan Commercial Corporation...
Page 6: Gas Supply
.18 psig (1.25kpa) coming out of the regulator. For liquid propane gas pressure coming into the regulator should be 11” WC or .4 psig (2.75kpa) and 10” WC .36 psig (2.5kpa) coming out of the regulator. ©2015 Hestan Commercial Corporation...
Page 7: Gas Pressure Regulator
All gas burners and pilots need sufficient air to operate. Large objects should not be placed in front of the appliance(s) that would obstruct the flow of air into the front. NOTICE: In the Commonwealth of Massachusetts all gas appliances vented by either mechanical systems or ventilation hoods shall comply with 248 CMR interlocking requirements. ©2015 Hestan Commercial Corporation...
Page 8: Electrical Supply
If the receptacle is not the proper grounding type, contact an electrician. Do not remove the grounding prong from this plug. Model / Serial / Rating Plate Locations Range tops Rating plate will be located above the front panel ©2015 Hestan Commercial Corporation...
Page 9: Operating Instructions
4) Re-install center ring. For daily shutoff: Turn burner valve knob(s) to the “OFF” position, pilot(s) will remain on. A 5 minute complete shutoff period is required before the appliance is re-lighted ©2015 Hestan Commercial Corporation...
Page 10: Cleaning And Maintenance
Heat tint can be removed by scouring with stainless steel wool or scouring powder. Rub in direction of polished lines. ©2015 Hestan Commercial Corporation...
Page 11: Service
Pilot not lit Burner not working well/lazy or yellow flame Gas pressure incorrect / incorrect regulator Orifice sized incorrectly Burner ports are obstructed or dirty Poor combustion, air fuel mixture not adjusted properly ©2015 Hestan Commercial Corporation...
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL