op. mode
Menu
4.2
op. mode
Setting range: auto, manual, add.
heat only
Default value: auto
functions
Setting range: compressor, addi-
tion, heating, cooling
The heat pump operating mode is usually set to "auto". It is also possible
to set the heat pump to "add. heat only", but only when an addition is
used, or "manual" and select yourself what functions are to be permitted.
Change the operating mode by marking the desired mode and pressing
the OK button. When an operating mode is selected, it shows what is
permitted in the heat pump (crossed out = not permitted) and selectable
alternatives to the right. To select selectable functions that are permitted
or not, mark the function using the control knob and press the OK button.
Operating mode auto
In this operating mode the heat pump automatically selects what functions
are permitted.
Operating mode manual
In this operating mode you can select what functions are permitted. You
cannot deselect "compressor" in manual mode.
Operating mode add. heat only
In this operating mode the compressor is not active, only additional heat
is used.
Caution
If you choose mode "add. heat only" the compressor is deselected and
there is a higher operating cost.
Functions
"compressor" is that which produces heating and hot water for the ac-
commodation. If "compressor" is deselected, a symbol in the main menu
on the heat pump symbol is displayed. You cannot deselect "compressor"
in manual mode.
Chapter 3 |