1. Gently release the clamps and unplug the two connectors
[1,2] that secure the ambilight panels. Release the clips
1
4.3.3
Small Signal Board (SSB)
Refer to
Figure 4-6
for details.
Caution: it is mandatory to remount all different screws at their
original position during re-assembly. Failure to do so may result
in damaging the SSB.
1. Release the clips from the LVDS connector that connect
with the SSB [1].
Caution: be careful, as these are very fragile connectors!
2. Unplug all other connectors [2] and the FFC connectors [3].
3. Remove all the fixation screws from the SSB [4].
4. The SSB can now be shifted from side connector cover,
then lifted and taken out of the I/O bracket. Refer to
Figure 4-6
for details.
2014-Jul-11
Mechanical Instructions
3
Figure 4-5 Ambilight Panel removal
from the FFC connector that connect with the AmbiLight
control panel [3].
2. Lift the AmbiLight panel from the rear cover. Make sure that
wires and flat foils are not damaged while lifting the
ambilight panel from the rear cover.