Sony CDP-CX50 Service Manual page 13

Table of Contents

Advertisement

QQ
3 7 63 1515 0
1. Grid check
PROGRAM
2. Segment check
Key Inputs Other than Buttons and How to Display
Key input
Rotate the JOG knob to
the right
Rotate the JOG knob to
the left
Press the JOG knob
(ENTER)
Door cover "Close"
Door cover "Open"
TE
L 13942296513
AGING MODE
• Mode which repeatedly changes and plays back discs automati-
cally in the unit.
• It will repeat aging as long as no errors occur.
• If an error occurs during aging, it will stop all servos, motors, etc.
instantaneously, display the error number, and stop operations.
However, the stopping conditions differ according to whether the
unit is equipped with the "self-protection function during errors"
described later.
The function serves to maintain the state of the unit when errors
occur.
www
.
http://www.xiaoyu163.com
REPEAT
REMOTE
2
--
-nn
1
Display
Fluorescent indicator tube block indicator
lights up in the order of 1 n 2 n ...8 n 1.
Fluorescent indicator tube block indicator
lights up in the order of 8 n 7 n ... 1 n 8.
Fluorescent indicator tube block indicator
goes OFF.
PLUS ONE LED lights up
PLUS ONE LED goes OFF
12345678
block indicator
x
ao
y
i
http://www.xiaoyu163.com
8
Sequence of Aging Mode
$
1. Disc change
$
2. Load in
$
3. TOC read
$
4. Access of last track
$
5. 3 second playback
$
6. Access of first track
$
7. 3 second playback
$
8. Load out
$
* DISC No. 40 chucks twice during one cycle.
To differentiate, the "8" on the block indicator of the fluores-
cent indicator tube will light up during the second chucking.
Q Q
3
6 7
1 3
Special Functions in Aging Mode
There are some useful function in the aging mode.
• Disc setting mode*1
• Switching of use/disuse of protection function in errors *2
• Aging cycle count function *3
*1 Disc setting mode:
5 discs are set before setting the aging mode. This mode makes
the setting of these discs more easy.
*2 Switching of use/disuse of protection function in errors:
Function which voluntarily corrects errors which occur during
normal operations by retries.
If this function is not provided, all operations will be stopped
without retiring. It is suitable for checking errors with low re-
producibility.
If this function is provided, and errors can be corrected by re-
tries, aging will be continued without stopping.
(The normal aging should be performed with "be".)
*3 Aging cycle count function:
Functions which displays the number of agings carried out on
the Fluorescent indicator tube in numbers. One aging cycle con-
sists of six discs.
DISC
51
u163
Disc number
.
— 13 —
2 9
9 4
2 8
Order of Disc Change
(1 cycle takes 3 minutes)
1 5
0 5
8
2 9
9 4
MIN SEC
TRACK
m
0.1
0.01
1
co
Agings carried
Track number
(Hexadecimal)
9 9
$
1. No. 51
$
2. No. 20
$
3. No. 40
$
4. No. 30
$
5. No. 10
$
6. N0. 40*
$
2 8
9 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdp-cx571

Table of Contents