Technical Specifications - Kärcher A 2204 Manual

Hide thumbs Also See for A 2204:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 6
in case of the formation of foam,
liquid escape or if the container is full!
Note: If the container is full, a float closes
the suction opening, and the suction
turbine works at a higher speed. Switch off
the appliance immediately, and empty the
container.
Blowing function
Use this function, for example, to blow out
leaves or dust from the garage, workroom
or work shop.
Attach the suction hose. Open the slide
of the air regulation, and select the
desired blowing performance
(0
max).
Finish operation
Empty the container.
➯ Wipe the appliance using a damp cloth.
Do not use any aggressive agents, such
as cleaning powder. If necessary, rinse
the accessories with water and let dry.
Note: Do not clean the appliance with a
water hose or high-pressure water jet!
Store the appliance in dry rooms.
Care / Maintenance
▲Before any care and maintenance
work on the machine draw out the
mains plug.
Changing the filter bag
➯ Poor suction – replace full paper filter
bag.
Order no. 6.959-130 (5x)
Changing the cartridge filter
➯ Poor suction – clean the filter under
flowing water and allow to dry before
inserting it into the appliance. Replace
the filter if damaged.
Order no. 6.414-552
8
ENGLISH
Warranty
In each country the warranty terms issued
by our authorized marketing company are
valid. We remedy any fault in the cleaner
free of charge within the warranty period
providing the cause of the fault proves to be
a material or manufacturing error.
Should you wish to call upon the guarantee,
please apply to your dealer or nearest
authorised Customer Service centre taking
along also the accessories and bill of sale.

Technical specifications

Nominal voltage
(1~50 Hz)
Fuse protection
(surge-proof)
Container volume
Water uptake
Fan data:
P Max
P Nom
Class of protection II
Mains cable: Type
Sound level
(EN 60704-2-1)
We reserve the right to introduce technical chan-
ges without prior notice
A 2204
A 2504
A 2254 Me
A 2554 Me
220-240 V
220-240 V
10 A
10 A
18 l
25 l
8 l
13 l
1200 W
1400 W
1000 W
1200 W
II
H05VV-
H05VV-
F2x0,75
F2x0,75
73 dB(A)
73 dB(A)