Datalogic DS2400 Installation Manual page 48

Table of Contents

Advertisement

5
SOFTWARE FEATURES
READABLE CODE SYMBOLOGIES
• EAN/UPC (including Add-on 2 and Add-on 5)
• 2/5 Interleaved
• Code 39 (Standard and Full ASCII)
• Codabar
Other symbologies available on request.
Code Selection
Decoding Safety
Headers and Terminators
Operating Modes
Configuration Modes
Parameter Storage
ENVIRONMENTAL FEATURES
Operating temperature
Storage temperature
Humidity max.
Vibration resistance
Shock resistance
Protection class
PHYSICAL FEATURES
Mechanical dimensions
Weight
The features given are typical at a 25 °C ambient temperature (if not otherwise
Note 1:
indicated).
Note 2:
Further details given in par. 3.3.
If the reader is used in high temperature environments (over 35 °C), use of the
Note 3:
Beam-shutter is advised (see the WinHost configuration program).
36
up to six different codes during one reading phase
can enable multiple good reads of same code
up to four headers and four terminators
On-Line, Automatic, Serial-On-Line, Test
• through menus using WinHost utility
• receiving commands from one of the serial ports (HOST
MODE)
Non-volatile internal EEPROM
0 to 40 °C (32 to 104 °F)
(Note 3)
-20 to 70 °C (-4 to 158 °F)
90% non condensing
IEC 68-2-6 test FC 1.5 mm;
10 to 55 Hz; 2 hours on each axis
IEC 68-2-27 test EA 30G;
11 ms; 3 shocks on each axis
IP65
68 x 83.4 x 34 mm (2.7 x 3.28 x 1.3 in)
330 g. (11.64 oz.)
• Code 93
• Code 128
• EAN 128
• Pharmacode
DS2400

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds2400 seriesDs2400-1 seriesDs2400-2 series

Table of Contents