ReSound Multi Mic User Manual

ReSound Multi Mic User Manual

Portable speech and audio streamer
Hide thumbs Also See for Multi Mic:

Advertisement

WIRELESS CONNECTIVITY
User guide

Advertisement

Table of Contents
loading

Summary of Contents for ReSound Multi Mic

  • Page 1 WIRELESS CONNECTIVITY User guide...
  • Page 2: Statement

    Congratulations on your purchase of a ReSound Multi Mic. The This device complies with Part 15 of the FCC Rules and ICES-003 Multi Mic is a high quality portable speech and audio streamer of the IC Rules. Operation is subject to the following two condi-...
  • Page 3: Intended Use

    Annex I of Council Directive 93/42/EEC for medical devices (MDD) and Essential Requirements and other relevant provisions of Directive 1999/5/EC (R&TTE). The declaration of conformity may be consulted at www.resound. In US: FCC CFR 47 Part 15, subpart C In Canada: IC 6941C-SM2P...
  • Page 4: Table Of Contents

    Microphone directionality ......18 Wearing the Multi Mic ....... 18 What is covered by this warranty? .
  • Page 5: Description

    Description Volume down Power button Mute button Microphone inlet Volume up Microphone inlet Status light indicator (LED) 10 Micro USB for charging Line-in 11 Mute light indicator (LED) FM connector 12 Mode and battery status light indicators (LEDs) 13 Mode button 14 Paring button 15 Mounting clip...
  • Page 6: Getting Started

    Getting Started • When charging your Multi Mic for the first time, let it charge for at least 3 hours, even if the battery indicator indicates that the Before using your Multi Mic, you need to charge the rechargeable battery is fully charged.
  • Page 7: Turning Your Multi Mic On And Off

    2. With the tip of a pen green every 2 seconds. or similar object, press To turn the Multi Mic OFF, press and hold the ON/ OFF button for the small pairing but- approximately 1.5 seconds, until the status LED turns red – indi- ton once, as shown in cating that the unit is shutting down.
  • Page 8: Start Streaming

    Pairing the Multi Mic in channel 2 or 3 (For people using more Start streaming than one streaming device) Turn ON the Multi Mic and make sure your hearing instruments To pair the Multi Mic in channel 2, press the pairing button twice.
  • Page 9: Stop Streaming

    1. Press and hold the hearing instrument program button for about 3 seconds two or three times in a row to access the 2nd Note! You may get out of range from your Multi Mic. If your or 3rd ReSound streaming device.
  • Page 10: Microphone Directionality

    Microphone directionality The Multi Mic can both be used for picking up the voice from one speaker wearing the Multi Mic as well as a table microphone solu- tion picking up the voices of multiple speakers. Wearing the Multi Mic...
  • Page 11: Status Light Indicator (Led)

    Status light indicator (LED) The LED on your Multi Mic serves as a multipurpose user inter- face, providing information on the status of your device. Power/Charging No charging Charging Fully charged Powered Off Powered On (Normal) Powered On (Volume control disabled and MIC or...
  • Page 12: Modes Of Operation

    In this mode the hearing background noise. aid user will wear the Multi Mic or have it nearby. The Multi Mic will now be able to transmit the received FM signal to When placed horizontally on a table, the Multi Mic will the hearing instruments.
  • Page 13: Using The Mode Button

    3 seconds until one or more of the Mode LEDs tus of the Multi Mic. starts to blink. - 75 – 100 % remaining battery capacity: All Mode LEDs blink Current mode: - 50 –...
  • Page 14: Volume Control And Mute

    Volume control and mute Volume control Note: The Multi Mic will revert to its default level for all modes when restarted. Multi Mic is designed to provide a comfortable listening level from the moment it is activated. However, for some devices or listen- ing environments you may want to adjust the volume.
  • Page 15: Mute Light Indicator

    Drop detection that the volume control is locked. In the event that the Multi Mic falls from a height of more than 75 cm (30 inches), a built-in sensor will mute the output streamed How to unlock the volume control to the hearing instruments for up to 2 seconds.
  • Page 16: Test Mode

    • When in Test mode the Status LED (see page 8) will be solid orange. • When entering Test mode the default volume is applied. If needed, volume can be adjusted on the Multi Mic until trans- parency has been verified.
  • Page 17: Important Information

    Note: Adjustments to reach transparency can be made on the Multi Mic and/or in the hearing instrument using the fitting • When the Multi Mic is not in use, turn it OFF and store it safely. software. • Protect the Multi Mic from excessive moisture (bathing, swim- ming) and heat (radiator, car dashboard).
  • Page 18: General Warnings

    • When using Multi Mic and the device is affected by electro- • If the hearing instruments do not respond to the device be- magnetic interference, move away from the source.
  • Page 19: Built-In Battery Care

    Battery performance is par- ticularly limited in temperatures well below freezing. • Do not use Multi Mic in areas where RF transmission is prohi- bited, e.g. air planes etc. • Do only connect Multi Mic to connections, which it is explicitly Battery warning intended for.
  • Page 20: Charger Care

    • For availability of approved enhancements, please check with your hearing care professional. Do not charge the Multi Mic while it is on your body. • Charge the product according to the instructions supplied with the product. Charger warning Use the device only with the power supply unit that has been supplied together with the product.
  • Page 21: Technical Specifications

    Your Hearing Care Professional may have The Multi Mic is covered by a limited warranty issued by the manu- issued a warranty that goes beyond the clauses of this limited facturer for a period of 12 months from the day of the original warranty.
  • Page 22: Troubleshooting Guide

    Unlock the volume control (see Volume control lock chapter) control level The Multi Mic and the hearing in- Assure that Multi Mic and the hearing instruments are within wireless strument are out of wireless range range There is no sound in the...
  • Page 23 The Multi Mic and the hearing Assure that the Multi Mic and hearing instruments are within wireless instrument are not within wireless range and repeat pairing process range...
  • Page 24 When using the line-in Adjust the volume using the “+” and “-“ buttons on the Multi Mic, or The audio level of the device con- the sound is too high or adjust the volume on the external audio device, until the best sound...
  • Page 25 Multi Mic CAUTION indicates a situation that could lead to minor and moderate injuries. Advice and tips on how to handle your ReSound ac- cessory better. Any issues relating to the EU Medical Device Directive 93/42/...
  • Page 27 Worldwide Headquarters Australia ReSound A/S GN ReSound Pty. Ltd. Lautrupbjerg 7 Gate C, 19-25 Khartoum Rd DK-2750 Ballerup, Denmark Macquarie Technology Park Tel.: +45 45 75 11 11 Macquarie Park NSW 2113 Fax: +45 45 75 11 19 Tel.: (free) 1800 658 955 www.resound.com...

This manual is also suitable for:

Micro mic

Table of Contents