R
epair
< 3 > Replacement of motor housing
1. Detach carbon brushes, pan head screw M5 and hex lock nut M5x8 which fasten motor housing
on angular guide, as illustrated in Fig. 4.
Pan head screw M5
Brush holder
cap
Carbon brush
2. Motor housing can be separated from blade case unit by removing 3 pan head screws M5x50
as illustrated in Fig. 5.
Pan head
screws M5x50
Angular
guide
Motor housing
Hex lock nut M5x8
Fig. 4
Armature
Fig. 5
P 5 / 11
Blade case unit