Code Faults
D05
OUTSI.S.FAIL.
D07
AUX.SENS.FAIL.
D09
DHW S.FAILURE
D11
ROOM S.A FAIL.
D12
ROOM S.B FAIL.
D13
ROOM S.C FAIL.
D14
MC COM.FAIL
D15
ST.TANK S.FAIL
D16
SWIM.P.B. S.FAIL
D16
SWIM.P.C. S.FAIL
D17
DHW 2 S.FAIL
D27
PCU COM. FAIL
06/09/2010 - 300024828-001-A
Cause
Description
of the
error
SCU
Fault external sensor
Remarks:
The boiler operates on BOILER
MAX temperature.
The valve setting is no longer
ensured but monitoring the
maximum temperature of the circuit
after the valve is ensured.
Valves may be manually operated.
Reheating the domestic hot water
remains ensured.
SCU
Auxiliary sensor failure
SCU
Domestic hot water sensor failure
Remarks:
Heating of domestic hot water is no
longer ensured.
The load pump operates.
The load temperature of the dhw
tank is the same as the boiler.
SCU
Fault room temperature sensor A
Fault room temperature sensor B
Fault room temperature sensor C
Note:
The circuit concerned operates
without any influence from the room
sensor.
SCU
Communication failure between the
SCU PCB and the boiler radio
module
SCU
Storage tank sensor failure
Note:
The hot water storage tank
reheating operation is no longer
assured.
SCU
Swimming pool sensor failure circuit
B
Swimming pool sensor failure circuit
C
Note:
Pool reheating is independent of its
temperature.
SCU
Sensor failure tank 2
SCU
Communication failure between the SCU and PCU PCBs
Contact the professional who takes care of maintenance of the appliance
4
Checking / solution
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Check the link and the connectors
4
Boiler module failure
Change the boiler module
4
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
7. Troubleshooting