3. Verify that the blower is operating and supplies the air low needed to maintain clean
combustion.
4. Open the gas control and light the burner according to the procedure required by the safety
standard.
5. Adjust the gas low to reach and maintain the desire temperature set by the user
6. Continue operation as long as:
• The water low is above the minimum required
• The presence of lame is veriied
• No unsafe condition develops
7. Provide the user with a visual indication of the operating conditions turning on the appropriate icon and displaying
the current outlet temperature:
• Fan icon on: Blower operating
• Flame icon on: Burner is lit and lamed is detected
• Shower Head on: Water is lowing
8. The button marked "C/F" determines if the temperature is displayed in °F or °C degrees
9. Whenever the "UP" or "Down" are pressed the display shows the set temperature.
10. If an unsafe condition is encountered and the unit shuts off, the display will show an Error Code corresponding to
the actual condition that caused the unsafe condition.
See Troubleshooting section for a list of all error codes.