Control Module and its Connections

MAINTENANCE

We recommend that the GSWH-2 water heater be inspected monthly by the user and at least once a year by a Girard
Products LLC recommended service technician.
Before an inspection, make sure that the Electrical Power, LP Gas and Water systems are turned on. Purge air out of
ALL hot and cold water lines. Verify that there are no combustible materials, gasoline or other lammable
vapors and liquids in proximity of the unit.
A routine inspection must include the following items:
1. Inspect the integrity of the sealing (caulking or tape) between the side wall and the door of the water
heater and ensure that the unit is solidly mounted to the vehicle.
2. Verify that the air inlet openings (louvers) are completely open and clear of any debris
including mud, leaves, twigs, insects etc. Remove all obstructions to allow full air low.
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing
Figure 13
CAUTION