Electrical accessories

CR - Remote Control. This device consists of a remote control
which allows all the control and monitoring functions of the control
unit on the machine to be controlled up to 100 meters away from the
actual machine itself. It has been specially designed for installation
on a wall inside the building. Use a threepole. The transmission line
must be routed in a dedicated duct, separate from any electric
powering lines (230/400 V). It has four keys used to select the con-
trols on the controller installed on the machine, the only difference
being that the scroll-up and scroll-down functions have been sepa-
rated from the mode and on-off keys in order to make the control
easier to use.
During normal operation, the operating temperature (or the temperature read by the probe on the exchanger inlet) in
degrees centigrade appears on the LCD display or the alarm code, if at least one is activated. The temperatures read
by the other probes can be read by means of a few simple operations.
If faults occur during normal operation, the controller stops the machine and displays the code of the alarm in question.
After the alarm has been checked and its cause eliminated, the controller can be reset by pressing the on/off key.
The remote control has the following keys:
The controller has five LEDs on the left-hand side of the interface, that display the status functions of the machine:
• LED of compressors 1 and 2 (circuit 1).
• LED of compressors 3 and 4 (circuit 2).
• Electric antifreeze heater LED.
• HEATING mode LED
• COOLING mode LED
MODE plus ON/OFF
OP - Programmer Clock. Allows the unit to be turned on and off, depending on the selected time settings (up to 14 settings
can be entered, divided as required throughout the 7 days of the week).
RAG (F) Electric antifreeze heating element on the storage tank. Plug type. It activates in parallel with the evaporator s antifreeze
heating element and keeps the water at a temperature able to prevent ice from forming during the winter, when the unit is not
used.

Mechanical options

Special finned heat exchangers
• Coils with copper fins
• Coils with tin-coated copper fins
• Coils with aluminium fins with acrylic coating

Electrical options

Power source voltage rating 230V-3-50Hz
10
OPTIONS AND ACCESSORIES
Selects the operating mode (waiting for start-up or operation) of
MODE KEY
the machine.
Allows the controller to be turned on and off and resets the alarms.
ON-OFF KEY
If pressed at the same time, are used to access and quit the various
KEYS
menu levels.
When the menu is displayed, is used to scroll forwards through the
UP KEY
items in the menu itself, or to increase the value of a parameter.
When the menu is displayed, is used to scroll backwards through the
DOWN KEY
items in the menu itself, or to decrease the value of a parameter.

Advertisement