Summary of Contents for Gardsman CTC-1241GT

  • Page 1 25-MAR-2010 For THIRKILD DENMARK...
  • Page 2: Table Of Contents

    Table of Contents 1. Application Overview _______________________________________________________ 1 1.1. Identifying the Parts_____________________________________________________________ 1 1.2. Insert GSM SIM Card ____________________________________________________________ 2 1.3. The Power Supply ______________________________________________________________ 3 1.4. Connecting the Wired Devices ___________________________________________________ 3 1.5. How to Install the Control Panel __________________________________________________ 4 1.6.
  • Page 3 2.5.6. SMS P-Word _______________________________________________________________________ 38 2.5.7. Remote Controller Entry Enable Select (RC Ent E) ____________________________________ 38 3. Configuring Your System ___________________________________________________ 39 3.1. Area __________________________________________________________________________ 39 3.2. GSM __________________________________________________________________________ 39 3.2.1 GSM Signal_________________________________________________________________________ 40 3.2.2 GSM Call Back ______________________________________________________________________ 40 3.2.3 GSM Reset _________________________________________________________________________ 41 4.Operation __________________________________________________________________ 42 4.1.
  • Page 4 4.13. Alarm Activation ______________________________________________________________ 50 4.14. Stop the Alarm and Alarm Display______________________________________________ 52 4.14.1. Stopping the Alarm ________________________________________________________________ 52 4.14.2. Alarm Memory ____________________________________________________________________ 54 4.15. False Alarm Management______________________________________________________ 54 4.15.1. Dual-Ply Entry Warning ____________________________________________________________ 54 4.15.2. Mis Operation Reporting ___________________________________________________________ 54 4.15.3.
  • Page 5: Application Overview

    1. Application Overview 1.1. Identifying the Parts Backlit OK Key To confirm the keyed-in data or confirm the selection. Backlit # Key — Press & hold for 2 sec to enter the Programming menu. Backlit — Press & hold for 2 sec to enter Installer menu.
  • Page 6: Insert Gsm Sim Card

    1.2. Insert GSM SIM Card Input/Output Contact Point & DC Terminal CTC-1241 Panel features built-in communication facility report Monitoring Station. To Insert your SIM card: < > < > It is recommended to disable the SIM Flash Update/KP-18 Wire (RJ-11-XH) card PIN code before inserting into the Connector Control Panel.
  • Page 7: The Power Supply

    1.3. The Power Supply For all other battery status, please CTC-1241GC is designed with an AC power refer to section 4.16. adapter built-in; hence, any power supplying to this unit should only be installed by a professional installer. 1.4. Connecting the Wired Take the electric wires from the electric outlet on the wall and connects the two wires to the Devices...
  • Page 8: How To Install The Control Panel

    1.5. How to Install the Control Panel When an identical PIN code is in both Areas 1 & 2, then that PIN code The easiest way to get to know the system becomes Global PIN. When entering and get it up and running quickly is to get Global PIN code in either area, you devices accessories...
  • Page 9: Getting Started

    Guardian Code During entering PIN code, if incorrect The Guardian Code has the same codes have been inputed for 4 times authorization as the PIN Code. It is or over 20 incorrect numeric numbers designed for patroller of the Central have been entered, it will inhibit Station.
  • Page 10: Installer Set Up

    2. Installer Set Up Regardless if any editing is made or This menu is for the installer to configure the not, whenever exiting installing mode, system which is inaccessible by users. a reporting (Contact ID event code 628) will be sent to the Central Step 1.
  • Page 11 Delete Tel. Numbers Step 3. Key-in desired phone number. Step 1. Apply Steps 1 & 2 from Store Tel. Numbers section on the number that Step 4. Press OK key to choose the reporting is wished to delete. priority sequence. key to cancel the numbers.
  • Page 12: Ip. Settings

    2.1.2 IP. Settings < > < > o C e n t r a l P o r t A d d r e s s If the Account number has not been A c c . n u m b e r entered, the Control Panel sends SMS A P N ( G P R S ) text...
  • Page 13 2.1.2.3 Acc. Number (2) Second Priority: For back-up reporting. It allows you to set/change/delete the Account The system excutes the reporting based on Number corresponded Central your setting as a back-up method. (see Monitoring Station IP Address that has been section 2.1.3.
  • Page 14: Sms Numbers

    2.1.2.4 APN (GPRS) 2.1.2.6 Password (GPRS) Access Point Name (APN) is the name of an The GPRS password is offered by your SIM access point for GPRS. Please inquire your card service provider accordingly. Please SIM card service provider for your APN. inquire your service provider supplier for your GPRS password.
  • Page 15: Back-Up Method

    (1) Back-up None (default): The system will Four dots are displayed to indicate no not report to any second priority IP Address telephone number has been set. nor phone number, unless all “First Priority” IP address/phone number failed. < > <...
  • Page 16: Installer Code

    2.2. Installer code The Installer Code is used to enter Installer Alternative (default) Menu. If the Alternative method is chosen, the Factory default: 7982 system will try reporting sequence in cycle of each IP addresses / Tel. numbers. A max of 5 To set the Installer Code: cycles will be tried.
  • Page 17: Area

    2.3. Area 2.3.1.1 PIN Code < > < > < > < > There are 2 operation Areas in each system, and each can be programmed There are two operation areas in the independently. system. Each area can be set / program individually.
  • Page 18 < > Step 9. Proceed to set additional User PIN < > Codes as instructed from Steps 1-8. The Latch rpt On/Off section display for your programming only when the Latch selection function is enabled < < > > (See section 2.5.4 under Configuring your system) To name the User Names, please refer to section 5.
  • Page 19: Master Code

    2.3.2 Master code Step 2. Move the cursor to the desired # (2-6) of programmed user PIN code to be Master Code is used to access the deleted, then press OK. The following Programming mode. screen is displayed: Master Code: 1111 D e l e t e p i n - c o d e Set as factory default.
  • Page 20 2.3.3.1 A. Entry Timer (Away Entry 2.3.3.3 H. Entry Timer (Home / Day Timer) Home / Night Home Entry Timer) When Door Contact (DC) or PIR Detector (IR) When Door Contact (DC) or PIR Detector (IR) is set as Entry / Away Entry / Home Access is set as Entry / Away Entry / Home Access attribute, the system gets into counting down attribute, the system gets into counting down...
  • Page 21 2.3.3.5 A. Entry Sound (Away Entry 2.3.3.9 Door Chime Sound) This function is available only when the attribute of Door Contact (DC) and/or PIR This is for you to decide whether the Control detector (IR) is set as Entry or Away Entry. Panel sounds count-down beeps and volume of beep during the Away entry timer (see The Control Panel sounds a Door Chime...
  • Page 22 2.3.3.11 Mobility 2.3.3.12 Local Siren This function is designed to avoid an accident This is used to program whether the Control (e.g. swoon or lost consciousness) happening Panel raises local alarm while a sensor is to the user without anyone notices. Under all triggered.
  • Page 23 2.3.3.14 Tamper Alarm When Report off is selected, the < > < > control unit will not report any AC This feature is only available for Area 1. failure. Changes made in Area 1 apply to both Once AC power is restored, an AC Areas 1 &...
  • Page 24 2.3.3.17 Siren Delay 2.3.3.19 Verification This is for you to decide how long should the This is to set the Sequential Verification Control Panel suppress the audible alarms Reporting. after a Burglar or Entry alarm is reported. o O n Options are Disable and 1 Min delay to 10 Min O f f delay in 1-Min increments.
  • Page 25: Sms Header

    2.3.4 SMS Header To change/delete the SMS header, The words, which you edit in SMS Header edit please follow same steps screen will display in the header of each SMS described above. alarm message reported to your mobile phone for easy recognition. For Example, if you enter your address in the 2.3.5 SMS Keyword SMS Header edit screen, your address show in...
  • Page 26 2.3.6.1 Add Devices Step 1. Select Add Device, then press OK, a A l r e a d y E x i s t prompting message is displayed. s y s t e m * P u s h B u t t o n O n * The screen will return to Step 1 D e v i c e...
  • Page 27 O for Home Omit Door Contact A for Home Access Door Contact When the system is in Away Arm When the system is in Away arm mode (incl. away arm entry), if a mode, if Home Access Door Contact Home Omit Door Contact is triggered, is triggered, a burglar alarm will be a burglar alarm will be activated activated immediately.
  • Page 28 After the delay period is expired and M for Medical Door Contact no correct PIN code is entered to The Medical Door Contact is active at disarm the system, the Control Panel all times and does not have to be will respond with a Burglar Alarm armed or disarmed.
  • Page 29 < > When the system is in Night Home < > arm mode, if N-Home Door Contact is key is pressed during the Edit triggered, a Burglar Alarm will be Name step, the Door Contact will use activated immediately. An event Code zone number to display instead of a of 130 will be reported.
  • Page 30 every 2 sec until the pre-defined Alarm B for Burglar PIR Detector Length expires. The LCD display O for Home Omit PIR Detector. remains unchanged. No reporting will be made. DO for Day Home Omit When EIR is triggered in Alarm off Detector.
  • Page 31: Remote Keypad

    StepD10. Follow the same learning procedure F for Fire Remote Controller as described in section 2.3.6.1 Add Control Panel will give a Fire alarm Device, steps A8-A9 to confirm when the panic button is pressed & learning & naming the device. held for 3 seconds or pressed twice I n s t a l l e d : ( O K ? )
  • Page 32 < > < > When set as Entry, when the Control Panel is in Alarm Off mode, entering KP-18 receive PIN code followed by pressing the acknowledgement signal, a prompt KP’s Disarm button, the Control Panel message “No response!” will be will emit 2 beeps.
  • Page 33 Single area means that BX-15 raises Step 4. Slide DIP SW1 on SR-15 function an alarm only when the sensor, which is switch block to ON position. SR-15 will learnt in this area, is triggered. emit a short beep and enters learning mode.
  • Page 34: Other Devices

    2.3.6.2. Edit Devices Step10. Select the zone number and press OK To edit all the devices that have already been key to confirm. Another prompting installed, choose Edit Devices in the Device message will displayed +/- menu, all the devices being included in the selecting its zone name.
  • Page 35 2.3.6.3. Remove Devices Step5A. Edit the zone name and press OK Adding a device for a second time is prohibited when completed to return to the unless it is removed from the system first. To previous device list. delete a device, choose Remove Device in the Device +/- menu Step6A.
  • Page 36 2.3.6.4. Program Siren Step 4. After exiting the auxiliary devices out < > < > of Learn mode, the learning process is Program Siren option will then complete. available in Device +/- menu only < > < > when detector Remote Controller has been added already.
  • Page 37 Entry Snd On, Entry Snd Off SMS Control: the power switch can only be controlled by SMS. This is to enable or disable all sirens to Burglar: When a burglar alarm is play Entry Delay warning beeps. triggered, PSS will turn on; when Disable the Siren Entry Sound by the system is disarmed, PSS will selecting Entry Snd Off.
  • Page 38: Walk Test

    Silence Panic: When a silent panic To Remove PSS alarm is detected, PSS will turn on; To remove a PSS from the system, simply when the system is disarmed, PSS select the channel, and change the attibute to will turn off. “Disable”.
  • Page 39: I/O Config

    Press key once again. The screen will Step 4. A NC (normal close) / NO (normal open) display: option is required to choose. A r e y o u s u r e q u i t ? o N O Press key to return to log record.
  • Page 40: Common. Setting

    Step 4. A NC (normal close) / NO (normal o D i s a b l e open) option is required to choose. 1 5 M i n 3 0 M i n o N C < > < > We e k s NC: The wired siren/light activates in We e k s...
  • Page 41: Supervision

    2.5.3. Supervision 2.5.4. Latch Select Latch report is sent while system mode is This option used enable system changed (e.g. from Away arm mode to Alarm supervision function. When ON is selected, off mode) and can be applied to control prompt CTC-1241 will be able to receive the check-in situation from the system.
  • Page 42: Sms P-Word

    2.5.6. SMS P-Word 2.5.7. Remote Controller Entry Enable Select (RC Ent E) SMS Program keyword is a password to authorize Remote Setting Remote This is to Turn On or Off the Remote Controller Upgrading. disarm function. SMS Program keyword is used to recognize the identity of a valid user, and to give authority E n t O p t...
  • Page 43: Configuring Your System

    3. Configuring Your Step 5. Then the Programming Main menu will System be displayed. < > < > o A r e a G S M There are two operation Areas in the system. Each area Step 6. Move the cursor to the desired item, set/programed individually.
  • Page 44: Gsm Signal

    3.2.1 GSM Signal 3.2.2 GSM Call Back CTC-1241 utilizes GSM as its telephone Before setting this feature, please place a interface communication purpose. SMS Remote Command to Panel for testing Selecting GSM Signal in the Programming purpose (See “Remote Commanding – via Main Menu can monitor the GSM signal.
  • Page 45: Gsm Reset

    3.2.3 GSM Reset Step 6. Enter the Country Code. GSM module will reset once OK is pressed, with 30 sec of time out period. < < > > Enter “886” as the country code. G S M R e s e t i n g R e p l a c e d n u m b e r 0 3 0...
  • Page 46: Operation

    4.Operation o A r e a 1 < > < > A r e a 2 A r e a 1 + A r e a 2 There are two operation Areas in the system. Each area When Area1 or Area2 is selected the set/programed individually.
  • Page 47: Away Arm Mode (Alarm On)

    4.2. Away Arm Mode (Alarm The system can also be armed by pressing the “LOCK symbol” the Remote controller (Only if the Remote Controller Entry option is Enabled). 4.2.1. Away Arming the System If the system is in Alarm off mode, and Away Arming the system is wished, please follow the 4.2.2.
  • Page 48: Home Arm

    4.3. Home Arm 4.4. Day Home Arm Home Arm Mode allows the home to be Day Home Arm Mode allows the home to be partially armed. Thus, part of the areas are partially armed during a particular time period protected with the Alarm, while others allow the (such as Day time) only.
  • Page 49: Night Home Arm

    4.5. Night Home Arm 4.6. Timer Night Home Arm Mode allows the home to be o T i m e partially Armed during a particular time period D a t e (such as Night time) only. Y e a r D a y l i g h t The area is recommended to set differently as Day Home Arm.
  • Page 50: Year

    4.6.3. Year Step 5. Select the starting hour and press OK. This is for you to set the current year. o - 2 H o u r s Y e a r S e t t i n g H o u r 2 0 0 8 O K ) H o u r...
  • Page 51: Forced Arming

    4.8.1. Arming the System via Control Panel Step 3. Press OK to confirm the selection. The selected device will be marked Step 1. Choose the preferred Arming Mode with a “ * ” symbol at the front to (Away Arm, Home Arm, Day Home indicate that device is now set as Arm or Night Home Arm) and press Bypassed.
  • Page 52: Arming The System Via Remote Controller

    4.8.2. Arming the System via 4.8.4. Arming with IR Triggered Remote Controller While arming the system, if any PIR Motion Detector is activated, the Control Step 1. Press once on Full Arm or Home Arm Panel will prohibit the Arming within 5 sec button.
  • Page 53: Pss

    4.10. PSS The log is marked with a Start label before < > < > the most recent entry, and End after the oldest entry. This feature is only available for already-learnt-in Power Switch. The number in the upper right corner indicates whether the event occurred in This system allows adding up to 8 Power Area 1 or 2.
  • Page 54: Alarm Activation

    4.13. Alarm Activation For Alarm Activation by Events and Control Panel Responses, please refer to the following table: Control Panel Mode & Response Table Away/ Home/Day Night Home/Day Away Home Away Arm Home/ Night Alarm attribute Disarm Home Home Home/ Night Entry Home Arm Home Arm...
  • Page 55 Away/ Home/Day Night Home/Day Away Home Away Arm Home/ Night Alarm attribute Disarm Home Home Home/ Night Entry Home Arm Home Arm Entry Exit Instant Fire Instant Instant Instant Instant Instant Fire Instant Fire Fire " F " Instant Fire Alarm Alarm Fire Alarm Fire Alarm...
  • Page 56: Stop The Alarm And Alarm Display

    4.14. Stop the Alarm and Alarm Display Step 4. The display will show you the device that triggered the alarm with its zone During any alarm, the Control Panel will sound number: its siren and report to the Central Monitoring A l a r m S t a r t e d Station and the display will show.
  • Page 57 4.14.1.2. Using Global PIN Code The following operaion will be based on this If 2 is selected scenario as an example: Step 2B.Press 2 to display the user menu. The < > < > alarm will be stopped and the display will show: Area 1 –...
  • Page 58: Alarm Memory

    4.15. False Alarm 4.14.2. Alarm Memory Management If an alarm is raised without being silenced CTC-1241 has 3 built-in regulatory false alarm during your absence, and the alarm reporting management facilities: has been carried out; the screen will stay on Dual-Ply Entry Warning the Alarm warning display.
  • Page 59: Faulty Situations

    4.16. Faulty Situations If the Control Panel does not receive The Control Panel is capable of detecting the signals transmitted from an the following fault events: individual sensor within the pre-set Supervision time, a Sensor out of Control Panel Low Battery order fault event will be displayed on Control Panel Battery Missing the screen and the system will send...
  • Page 60: Fault Message Display

    4.16.1. Fault Message Display 4.16.3. Viewing/Clearing the Fault Message When any fault situation persists, the Control Panel will respond as below when To check what the fault condition is: it is in Alarm off mode: Step 1. When the system is in Alarm off mode. The Yellow LED will light to indicat Enter your PIN Code followed by OK.
  • Page 61: Fault Event Response

    4.16.4. Fault Event Response Panel Sabotaged When a fault condition is detected, in addition to the fault display, the Control < < > > Panel will also respond separately Please refer to 3.3.13. Tamper alarm according to the nature of the fault event. under section General Setting to set AC Power Fail / Restore the tamper alarm reporting method.
  • Page 62: Fault Message Nomenclature

    Sensor Out-of-Order (Indoor/outdoor Siren) Siren out-of-order + out If the Control Panel can’t receive the signals transmitted from an GSM out of Signal ― GSM Signal individual sensor over the preset supervisory period, a Lost of signal GSM module missing ―...
  • Page 63: Remote Commanding

    4.17. Remote Commanding 2nd Power Switch Open for 1 52101~52199 Hour to 99 Hours The Unit can be controlled by Remote Control Commands sent via regular phone call or SMS Power Switch Open for 1 53101~53199 messages. Hour to 99 Hours Power Switch Open for 1 54101~54199 Via SMS message...
  • Page 64 Step 6. Enter the Control Command. Step 6. Enter the Control Command. Step 7. Enter a space. Step 7. You have now completed to edit the command message. You can send it Step 8. Enter 00. to the panel. Step 9.You have now completed to edit the <...
  • Page 65: Ctc-1241 Sms Remote Installing Command

    CTC-1241 SMS Remote Installing Command SMS Remote Installing Command Table is set as PROG, and default Install Code is 7982. If the SMS Program Word (SMS P-Word) ITEM COMMAND USAGE DESCRIPTION Max. 15 digits SMS P-word KEYWD PROG 7982 KEYWD:Jack It is used to change the SMS P-word PROG 7982 1=Area1, Max.
  • Page 66 ITEM COMMAND USAGE DESCRIPTION PROG 7982 Enter the APN Server detail (provided by your telecom supplier) APNSR APNSR:INTERNET (Max.30 digitals) PROG 7982 Enter the IP Address (provided by your CMS supplier) TCIP1:A1192.168.1.234 A1192.168.1.234 A = First Priority; 1=IP Address TCIP1 PROG 7982 Enter the IP Address (provided by your CMS supplier) TCIP1:B1192.168.1.234...
  • Page 67 ITEM COMMAND USAGE DESCRIPTION PROG 7982 BAKUP:0 To set back up method (for both Areas): Back up None Back-up BAKUP PROG 7982 BAKUP:1 Method Back up 1 Back up 2 PROG 7982 BAKUP:2 To set retry method (for both Areas): PROG 7982 ASSIG:0 One by one Retry Method...
  • Page 68 ITEM COMMAND USAGE DESCRIPTION PROG 7982 SUPPR:00 Supervision Function disable PROG 7982 SUPPR:04 4 Hours Supervision SUPPR PROG 7982 SUPPR:06 6 Hours PROG 7982 SUPPR:08 8 Hours PROG 7982 SUPPR:12 12 Hours PROG 7982 SUPPR:24 24 Hours To set Latch Select option function (for both Areas): PROG 7982 LATCH:0 Latch select Latch Select...
  • Page 69: Appendix

    5.Appendix 5.2. Reset Procedure 5.1. Device Naming Reset to Factory Default Setting Each individual User or detector can be given a name for easy recognition when understanding The Control Panel can clear all programmed system events. User Names or device names parameters by the following sequence: can be named when first setting them or by editing them afterwards when resetting them.
  • Page 70: Gprs Connection Protocols

    5.3. GPRS Connection 5.4. Communication Protocol Protocols & Format CTC-1241 Control Panel communicates with This protocols is used to transmit SMS Central Station receiver by using Contact-ID messages. However, different Central protocol. Monitoring Stations may provide different Control Panel RECEIVER protocols for end user.
  • Page 71 5.4.6. Message Composition 5.4.7. Data Tone The form of the message is: The message is sent using standard DTMF tones. Where ACCT MT QXYZ GG C The timing of the tones shall be as follows: = 4 Digit Account number (0-9, B-F) ACCT Burst ON time –...
  • Page 72 5.4.9.4. Burglar Alarms Smoke Detector 130 - Burglary WS Detector When any one of the following devices is triggered: The Door Contact (DC) set as 5.4.9.6. 24-Hour/Non-Burglar Burglary or Home Access (@ B or A) 1150 - 24H Special Door Contact The Door Contact (DC) set as 24 When the DC set as 24H Special is Hours (@ H)
  • Page 73 384 - Sensor Low battery 465 - Device Alarm Cancel (SD/PB/WTR) When the battery voltage of any one When the alarm from Panic Button of the following devices is low. (PB) or Wrist Transmitter (WTR) is cancelled within 8 seconds Door Contact When an alarm is triggered by SD PIR Sensor...