Table of Contents 1. Application Overview ....................1 1.1. Identifying the parts ....................1 1.2. The Power Supply ....................2 1.3. Connecting the telephone line ................2 1.4. How to install the Control Panel ................2 1.5. Two-Level Passwords .................... 2 1.6.
1. Application Overview OK Key 1.1. Identifying the parts — To confirm the keyed-in data or confirm the selection. # Key — To enter the Programming menu — For Telephone Number Setting; The system will dial as it is entered. ...
Be sure only to use an adapter provided. with the appropriate AC voltage rating to Hook the CTC-1131 unit onto the Wall prevent component damage. A DC 9V output Mounting Cross Bracket (holding the unit and 500mA adapter is generally used to power with the front facing you).
Page 5
of the screen indicating the system is in Away mode (this is the default mode) Step 3. Press 1 key on the keypad, the display will show. E n t e r C o d e . . . Step 4.
also scrolled down or up respectively. 2. Configuring Your System The following items can be selected. W a l k T e s t 2.1. Entering Programming Mode T e l . S e t t i n g s G e n .
Page 7
In Tel.Settings menu, select Tel.Numbers, < > < > the screen allows you to set/change/delete The maximum length of a number is the emergency telephone numbers. 20 digits including & #. If this A maximum of six numbers can be stored length is reached, the Control Panel in priority order (in the order of A.
Step 4. Press OK, then the previous stored S t a r t R e c o r d i n g number will be deleted. A f t e r t h e B e e p Step 3. After 2 sec, the Control Panel will Special Characters for Setting sound a long beep, the following Two special keys *...
....Pressing will return you to the menu with the list of numbers. Step 3. Control Unit will dial the number and play messages starting with address message ending with...
Page 10
then press OK the following screen is 4 ) ..displayed. < > < > 1 ) 2) MRS. SMITH representing the User 2 ) ..#2 PIN code is set up and user name 3 ) .
letter by the same method. following steps: The keys have the following functions: Step 1. Move the cursor to the item Pin Code then press OK the following screen will show the status of each User PIN 2ABCabc code: 3DEFdef...
above. to the zone that a Door Contact or PIR Detector is installed and is set to < < > > Entry. Master code 2.3.6. A .Exit Time (A way Exit Time) deactivated as the User #1 PIN Code. This is for you to select the Exit Delay time when Full Arming.
Page 14
Point Door Contact or PIR Detector is activated 2.3.12. Panel Siren while the system is in Disarmed mode. This is for you to decide to enable or disable the Control Panel built-in Siren when there is D o o r C h i m e an alarm event..
Delay period when Home Arming. For more description of this feature, please refer to Sec. II Away (Alarm E x i t S n d On) Mode of Operation. E x i t S n d O f f 2.3.20. Remote Controller Entry ...
When this option is occurred in advance to reset the timer: chosen ON, CTC-1131 will be able to receive the check-in signals from its system devices to In Home mode: whenever any indicate their proper functioning.
Page 17
Step 1. To learn in a sensor, move the cursor S t o p to the position Add Device, then Step 6. Use & keys to move the cursor to press OK, a prompting message is displayed. the desired zone number then press * P u s h B u t t o n O n *...
Page 18
Exit Delay period, if a Home Access H o u r Door Contact is triggered, the Control F i r e Panel does not respond. M e d i c a l E m g W a t e r ...
Page 19
StepA9. Press OK when zone name entering When the system is in Home arm is completed. The display will show mode, if an Part Entry Door Contact the new zone name with the attribute is triggered, the Control Panel will not next to the device and prompt you to respond.
or just press OK for no name. enter up to 10 letters as you please Please see section Device Naming for the name followed by OK or just for details. press OK for no name. Please see section Device Naming for details. E n t e r N a m e + O k...
Page 21
for burglar mode. Device Naming 2.4.2. Edit Devices Detectors can be given names and location descriptions to help understand system events. To edit all the devices that have already been The devices can be named when first installing installed, choose Edit Devices in the Device them or by editing them afterwards, the +/- menu, all the devices being included in the procedure is similar for both situations.
Page 22
Step5A. Edit the zone name and press OK Step 3. Press OK. Deleting a device is now when completed to return to the completed. The screen returns to previous device list. previous device list. Step6A. Proceed to edit other devices or <...
Page 23
while the UR-8 status LED lights up selecting Siren Tamp.On and press for 3 seconds. OK. All added sirens will be enabled with Tamper protection simultanously. Step 5. Place these auxiliary devices out of < > < > Learn mode. Adding them into the ...
2.4.5. Program PSS 2.5. Walk Test The Control Pannel is able to learn in Power When Walk Test is selected, the Green & Switch(es), please follow the steps below. Yellow LED’s will flash 3 times with 3 beeps, and the following two test patterns Before adding PSS, any least one other type of are displayed for 2 sec.
enter your pin Code, the above screen will also be displayed. 3. Operation 3.1. Entering User Menu After 30 seconds of key-inactivity, the system will automatically exit User When the system is in Disarmed mode (Alarm Menu and return to Alarm off mode. off), entering a valid user code can access the user menu, the system can then be Away armed or Bypass armed via this menu.
using the Remote controller (Optional). the middle of the top display row and alternates at 2-second intervals with individual fault events. 3.2.2. Stopping the Exit Delay < > < > The Exit Delay can be stopped by disarming the system. In the same situation, if you arm the system by pressing the Arm button on Step 1.
3.3.1. A rming with Door Opened 3.5. Home Arm Mode While you arm the system, if any door was The Home mode allows the home to be Armed detected opened, the Control Panel will so that no one can get inside without first also sound a ding-dong warning sound to Disarming the system, yet the person already indicate...
3.5.4. Forced A rming Step 6. Press OK to confirm the selection. If there is any fault condition or a door was The selected zone will be marked with found opened before or any sensor is a character in front of it to indicate triggered, when you press OK in step 3 that device is to be by-passed.
3.7. Alarm Activation For Alarm Activation by Events and Control Panel Responses, please refer to the following table: Control Panel Mode & Response Table Type of Alarm Away Away Arm Home Arm Disarmed Home Arm Exit Alarm Abbr Entry Entry Instant Instant...
< > < > 3.8. Stop the Alarm and Alarm is pressed or if no key is Display pressed within 10 sec. the screen returns to 1 device display. You can During any alarm, the Control Panel wil sound repeat from the beginning to view the its siren and dial the Emergency Telephone alarm event one more time.
Step 5C. Press OK, the display returns to The alarm log memorises the last 20 system Alarm off. events including < > All Alarm Events with Device ID < > All Fault Warning Events When an alarm (other than Panic Alarm) is raised, press the Disarm ...
Power Supply Lid from being opened or removed. 3.11. False Alarm Management PIR Sensor For IR-8 & 8 CTC-1131 has a regulatory false alarm management facility built-in: Tamper switch protects enclosure from being opened. Dual-Ply Entry Warning ...
Page 33
If the Control Panel can’t receive the Enter your PIN Code followed by OK. signals transmitted from an individual Step 2. The screen will display sensor for a supervisory period, that is set on Page 14 / 24. Supervision, sensor F a u l t D s p out-of-order fault event will be detected.
AC Power Fail ― Fault Condition Message displayed After AC power is failed for 15 sec, the yellow LED will light and the fault ― AC Power Fail AC failure message will be displayed. After I hour, if the AC power is not restored, the Control Panel ―...
8~20seconds. Control Result Command Step 3. You will hear 2 beeps from the Control Panel via phone set. Hang up the phone Step 4. Enter the user Pin code (user 1 ~ user Listen-in Step 5. If the Pin code is correct, you will hear Disarm 2 beeps from the Control Panel via phone set.
Page 36
If more than one number is programmed If the 2-minute listen-in period is up, the Control Panel will continue to dial the the CTC-1131 will automatically hang number(s) until two emergency calls are up the line. successfully answered with either 0, 1 or ...
Control Panel will only send the identity code, it will not play the message call considered to be successful. The same pager number will be dialed only once. 4. Appendix 4.1. Reset Procedure Reset to Factory Default Setting The Control Panel can clear all programmed parameters by the following sequence: 1.
Need help?