DSC PC1616 Installation Manual page 5

Power series
Hide thumbs Also See for PC1616:
Table of Contents

Advertisement

AUX Power Wiring
The control panel can provide a maximum of 700mA of current for modules, powered detectors, relays, LEDs, etc. If the total current required exceeds
700mA, an additional power supply is required (e.g., PC5200, PC5204). See list below.
Min/max operating voltages for devices, sensors and modules is 9.5V
PGM Wiring
PGMs switch to ground when activated from the control panel. Connect the
positive side of the device to be activated to the AUX+ Terminal. Connect the
negative terminal to the PGM.
Current output is as follows:
PGM 1, 3, 4 50mA
PGM 2 300mA
2-Wire Smoke Detectors Initiating Circuit
• Style B (Class B), Supervised, Power Limited
• UL Compatibility Identifier PC18-1
• DC Output Voltage 9.8-13.8 VDC
• Detector Load 2mA (MAX)
• Single End-of-Line (SEOL) Resistor 2200Ω
• Loop Resistance 24Ω (MAX)
• Standby Impedance 1020Ω (ΝΟΜ)
• Alarm Impedance 570Ω (MAX)
• Alarm Current 89mA (MAX)
UL Compatibility ID For FSA-210B Series is: FS200
2-Wire Smoke Detectors
Carbon Monoxide Detector Wiring
POWER
-
PC1616/1832/1864
ZONE
INPUT
-
(SEOL TYPE 41)
RM-1/RM-2
POWER LOOP
SUPERVISORY
RELAY
(12V
, 35mA)
DC
Telephone Line Wiring
Wire the telephone connection terminals (TIP, Ring, T-1, R-1) to an RJ-
31x Connector as indicated. For connection of multiple devices to the
telephone line, wire in the sequence indicated. Use 26 AWG wire
minimum for wiring.
Telephone format is programmed in option [350].
Telephone Call Directions are programmed in options [351]-[376].
PowerSeries PC1616/PC1832/PC1864 Installation Guide
CO DETECTOR
ALARM
TROUBLE
+
NC
C
NO NC
C
NO
SEOL
RESISTOR
(5600 ohm)
ALARM
INITIATING
LOOP
RESISTANCE
100 ohm
- 14V
DC
DC.
For current levels greater than 300mA, a relay is required. PGM2 can also be
used for 2-wire smoke detectors.
NOTE: Use SEOL resistors on fire zones only.
LED output with current limiting resistor and optional relay driver output.
4-Wire Smoke Detectors
The following hardwired CO detector models can be used with
PC1616/PC1832/PC1864 (and higher) control panels:
• Potter model CO-12/24, UL File #321434
• Quantum model 12-24SIR, UL File E186246
• NAPCO model FW-CO12 or FW-CO1224, UL File E306780
• System Sensor model CO1224, UL File E307195
NOTE: For multiple unit connections, the leads between CO detectors need to be
broken. The power supervision relay has to be powered from the last detector in the
loop.
Wireless CO detectors are also available. When installing wireless CO detectors,
use only DSC model WS4913. A DSC wireless receiver model RF5132-433 v5.1
(and higher) or DSC keypad receiver models RFK55XX-433 (xx=00/01/08/16/64)
v1.2 (and higher) are required when installing wireless CO detectors. For more
details on either the WS4912 CO detector or the receivers, refer to their respective
installation manuals.
BRN
T-1
GRA
R-1
GRN
TIP
RED
RING
- 5 -
RJ-31X

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc1832Pc1864

Table of Contents