  • Page 1: Combination Boiler

    Heating and Instantaneous Domestic Hot Water with TSS Fanned Flue system Installation and Operating instructions Calydra comfort Calydra comfort 100 Manufactures N° Model Type Gas Council N° 200906789037.31 Calydra comfort 80 Nat 47 - 980 - 22 200906790037.31 Calydra comfort 100 Nat 47 - 980 - 23...
  • Page 2: Customer Care

    These instructions are suitable for the following boilers : Calydra comfort 80 Calydra comfort 100 Do not forget the Logbook! Chaffoteaux & Maury supports Benchmark, the heating industry code to ensure the correct installation, commissioning and servicing of domestic central heating systems.
  • Page 3: Table Of Contents

    Contents Page Page CUSTOMER CARE..........System Controls ..........Guarantee ............Bypass and pump..........Statutory Requirements ........Expansion Vessel ..........Contents.............. Filling Point ............INTRODUCTION..........COMMISSIONING AND TESTING ..... DESCRIPTION............ Pre-commissioning ..........Location of components ........Domestic Hot Water ..........TECHNICAL DATA ..........Central Heating............
  • Page 4: Description

    Description Location of components 1. - Air pressure switch 2. - Steel chassis complete with expansion vessel 3. - Flue hood with fan 4. - Main heat exchanger 5. - Combustion chamber 6. - Multi- gas burner assembly comprising ignition and ionisation electrodes 7.
  • Page 5: Technical Data

    Technical data Calydra comfort Calydra comfort PROPANE L.P.G. G31 Appliance category Cat Il Cat Ii 2H 3+ 2H 3+ Gas rate Heat Gross input C/H & DHW Maximum in kW 28.7 34,6 Maximum in kg/h 2.00 2.42 Maximum in Btu/h 98000 117900 Maximum in ft...
  • Page 6: Dimensions

    Type C 32 xx Type C 32 xx Type C 32 xy Type C 32 xy Fig. 4 Weights Tails diameter With packaging : - Calydra comfort 80 : 39,5kg ø Safety valve outlet 15 mm - Calydra comfort 100 : 40,5kg ø...
  • Page 7: Operation

    Operation reset Fig.5 Domestic Hot Water Mode is controlled by the hot water control thermistor d (fig. 6) and the heating control thermistor e (fig. 6), but dependant upon In order to supply hot water, the main switch 23 (fig. 5) must to the position of the DHW temperature adjustment knob 24 be in ON position I This will be confirmed by the green (fig.
  • Page 8: Installation Requirements

    Installation requirements Location The boiler can be installed on any suitable internal wall. Ventilation Provision must be made to allow the correct routing of the flue The room in which the boiler is installed does not require specific and siting of the terminal to allow the safe and efficient ventilation.
  • Page 9: Installing The Boiler

    Installing the boiler Please check that you are familiar with the installation requirements before commencing work.(section 6) Method of positioning the boiler on the wall. The paper template can be used to ensure the correct positioning of kitchen cabinets etc. It also details the commissioning instructions.
  • Page 10: Making The Electrical Connections

    Installing the boiler (continued) Room thermostat T.A. Connector D main supply cable Fig. 11 Making the Electrical Connections: Connect the live and neutral wires of the main cable. Note: The connections should be made so that should the lead be pulled from its anchorage, the current carrying wires become taut before the earth wire.
  • Page 11: System Guidance

    System guidance The boiler is suitable for sealed systems only. The Fernox Manufacturing maximum cold water mains pressure for the appliance is 10 Britannica Works bar. All fittings and pipework connected to the appliance Clavering should be of the same standard. If there is a possibility of Essex the incoming mains pressure exceeding 10 bar, particularly CB11 4QZ...
  • Page 12: Commissioning And Testing

    Commissionning and testing Pre-commissioning Turn the boiler thermostat to maximum 25 (fig 17). Ensure that the system has been adequately flushed. The boiler will light. Purge gas supply of air and test for soundness. Allow the boiler to heat system. Carry out final electrical tests to ensure the correct polarity Check the inlet gas pressure (working pressure) while boiler and earthing continuity.
  • Page 13: User's Instructions

    User’s instructions Control panel (fig 17) 30 “RESET” Reset button 31. Pressure gauge 23. Two position Selector switch =- DHW mode indicator = Switched OFF =- Heating mode indicator = Switched ON = Domestic hot water temperature control knob Isolating Taps (fig 16) = Heating flow temperature control knob taps shown in Open position 26.
  • Page 14: Instruction For Setting The Built In Clock

    Instruction for setting the built in clock (if fittied) 1. General layout The mechanical clock covers a 24 hour period. Each tappet represents 15 minutes A (fig. 19). An override switch is located on the clock B (fig 19). 2. To set the time To set the time of day, grasp the outer edge of the dial and turn slowly clockwise until the correct time is lined up with the arrow C (fig.
  • Page 15: Incorrect Function

    Incorrect function Incorrects functions is signalled by leds (rep 26) display flashing correspond with chart below. CODE FAULT INFORMATION 30 40 50 60 70 80 H H H H H G Overheating safety feature H H H H G H Overheating defect without locking H H H H G G Misfiring safety feature...
  • Page 16 Chaffoteaux & Maury are continuously improving their products and therefore reserve the right to change specifications without prior notice and accepts no liability for any errors or omission in the information contained in this document. Manufacturer: Chaffoteaux & Maury - France Commercial subsidiary: MTS (GB) Limited MTS Building Hughenden Avenue...