Operation
The fluid level must be at least 3 cm (SCP
6000) or 8 cm (SCDP 7000) for the pump to
suck in automatically.
Insert the mains plug into the socket.
Automatic operation
In the automatic mode, the level switch au-
tomatically controls the pumping opera-
tions. The pump switches on or off when
the fluid level reaches the height that has
been set.
Ensure that the level sensor is not obstruct-
ed in any way.
The figures of the following special accessories can be found on page 4 of these instruc-
tions.
6.997-346.0 Suction hose, by the
meter, 1"(25.4mm)
25 m
6.997-359.0 Pump connection
G1 (33.3 mm) incl.
Check valve
In manual opertions the pump remains
switched on continuously.
Note:
Dry run leads to increased wear and tear;
do not leave the pump unattended when it
is running. Switch off the pump within 3
minutes of dry running.
Note
Contaminations can accumulate and lead
to malfunctions.
The appliance is maintenance-free.
Special accessories
Vacuum-tight spiral hose, to be cut into individual
lengths.
Suitable for 3/4" (19 mm) or 1" (25.4 mm) hoses.
With G1" (33.3 mm) threaded connection. Insert the
backflow valve instead of the flat seal to prevent the
water from returning into the pump.
Manual operation
Finish operation
Rinse the pump with clean water after
use.
Especially after running chlorinated wa-
ter or other liquids that leave residue
behind.
Disconnect the main plug from the
socket.
Maintenance and Care
Maintenance
Storage
Store the appliance in a frost free area.