Advertisement

IVO SMART 12/30-2 & 12/50-2
1
General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
Safety guidelines & measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
Technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
7
Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
8
Trouble shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
9
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
10
EC declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
11
Data sheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Appendix A
12
Installation sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Appendix B
MASTERVOLT
Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands
Tel. +31-20-3422100 / Fax +31-20-6971006
USERS MANUAL
117 Volt battery charger
-export models / U.S.A. version-
V2.0 March 2004

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IVO SMART 12/30-2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mastervolt IVO SMART 12/30-2

  • Page 1: Table Of Contents

    USERS MANUAL IVO SMART 12/30-2 & 12/50-2 117 Volt battery charger -export models / U.S.A. version- General information ............. . .2 Safety guidelines &...
  • Page 2: General Information

    MEASURES GENERAL INFORMATION GUARANTEE SPECIFICATIONS LIABILITY Mastervolt guarantees that this unit has been built accor- Mastervolt can accept no liability for: ding to the legally applicable standards & specifications. Should work take place, which is not in accordance with • damage due to use of the battery charger;...
  • Page 3: Technical Data

    0,7V the output Mastervolt Amsterdam. The IVO series goes with a family voltage needs to be compensated. We can compensate of advanced quality battery chargers. Mastervolt distribu- this voltage drop by removing the “diode compensation”...
  • Page 4: Installation

    TECHNOLOGY INSTALLATION THE BATTERY CHARGER AS FLOAT CHARGER Phase 3: Trickle charge, “FLOAT” It is possible to use the charger as a “trickle” charger. The The third stage, “FLOAT”, starts when the “absorption” charger supplies a constant output voltage of 13.25V phase has been completed.
  • Page 5 INSTALLATION WIRING AND CONNECTIONS (see also chapter 12) AC power supply When connecting any auxiliary equipment and/or a batte- Check the voltage of your IVO charger and power source. ry isolator, proceed as follows: This must be between 90 and 160 VAC. •...
  • Page 6: Operation

    INSTALLATION OPERATION BATTERIES 2 battery set 3 battery set INDICATOR LEDS BI 702 BI 703 FLOAT The battery charger is in a “trickle charge” For a proper installation, see the connection diagram in- mode, batteries are 100% charged. cluded with the battery isolator. Steps: ABSORPTION 1 Check if the charger, the main supply and the DC- The batteries are still being charged,...
  • Page 7: Trouble Shooting

    Charge voltage too high Check jumper ‘battery isolator’ on front panel. If you cannot solve the problem with this fault finding table, contact your Mastervolt Service Center. For a detailed distributor list, see www.mastervolt.com or contact our main office in Amsterdam, tel. +31-20-3422100.
  • Page 8: Maintenance

    Herewith declares that: Product: IVO battery charger Model: IVO Smart 12/30-2, 117V IVO Smart 12/50-2, 117V Is in conformity with the provision of the EC EMC directive 89/336/EEC and amendments 92/31/EEC and 93/68/EEC. The following harmonized standards have been applied:...
  • Page 9: Mastervolt

    APPENDIX A & B IVO SMART 12/30-2 & 12/50-2 117 Volt battery charger -export models / U.S.A. version- MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands Tel. +31-20-3422100 / Fax +31-20-6971006 V2.0. March 2004...
  • Page 10: Mastervolt

    IVO Smart Appendix A...
  • Page 11: Data Sheets

    DATA SHEETS DATA SHEETS IVO SMART 12/30-2 - 117V MAIN INFORMATION Design by MASTERVOLT Manufacturer ISO 9001 certified Model / name IVO Smart 12/30-2 Product battery charger/rectifier Article no 43113010 Colour • RAL 5021, wasserblau • RAL 7037, grey • RAL 9006 silver grey Weight excl.
  • Page 12: Mastervolt

    • Generic immunity standard : EN 50082-1:1997 • LLOYDS, DNV, ABS Mastervolt has constructed this product for rugged circumstances in professional or leisure situations. This product can be type-approved individually. Price approx. US $ 1500 per certification. • MANUFACTURED UNDER ISO 9001.
  • Page 13: Mastervolt

    DATA SHEETS IVO Smart 12/30-2 battery charger. Main PCB of the IVO Smart 12/30-2. ACCESSORIES & REMOTES Article no description 70404100 basic remote control LED’s 70403050 standaard remote contol LED’s current control advanced remote control display with owner’s settings 41500500...
  • Page 14: Mastervolt

    DATA SHEETS Set points register Setpoint Min. bulk time min. Temperature variation mV/C • Temperature variation Return to bulk time sec. 5.0 mV/°C 5.0 mV/°C per cell Return to bulk voltage 13.00 V • Reference voltage 25°C • Battery charging is not allowed Max.
  • Page 15: Mastervolt

    DATA SHEETS DATA SHEETS IVO SMART 12/50-2 117V MAIN INFORMATION Design by MASTERVOLT Manufacturer ISO 9001 certified Model / name IVO Smart 12/50-2 Product battery charger/rectifier Article no 04-31-15010 Colour • RAL 5021, wasserblau • RAL 7037, grey • RAL 9006 silver grey Weight excl.
  • Page 16: Mastervolt

    • Generic immunity standard : EN 50082-1:1997 • LLOYDS, DNV, ABS Mastervolt has constructed this product for rugged circumstances in professional or leisure situations. This product can be type-approved individually. Price approx. US $ 1500 per certification. • MANUFACTURED UNDER ISO 9001.
  • Page 17: Mastervolt

    DATA SHEETS IVO Smart 12/50-2 battery charger. Main PCB of the IVO Smart 12/50-2. ACCESSORIES & REMOTES Article no description 70404100 basic remote control LED’s 70403050 standard remote contol LED’s current control advanced remote control display with owner’s settings 41500500 IVO Smart temperature sensor IVO Smart 12/50 cable set IVO Smart remote cable set...
  • Page 18: Mastervolt

    DATA SHEETS Set points register Setpoint Min. bulk time min. Temperature variation mV/C Return to bulk time sec. • Temperature variation Return to bulk voltage 13.00 V 5.0 mV/°C 5.0 mV/°C per cell Max. bulk/abs time min. • Reference voltage 25°C •...
  • Page 19 The standard remote panel absorption The standard remote panel is a useful power device for remote control of the Mass an IVO smart Mastervolt battery chargers. The standard remote control does indicate the on - bulk charge current output status of the charge control by six high power leds and control the output current by setting the potential meter.
  • Page 20: Mastervolt

    Inverter Control Charger Control The basic remote panel is a useful power device for remote Charger Output control of the Mass an Ivo smart Mastervolt battery chargers. failure The basic remote control does indicate the status of the charge absorption control by six high power leds.
  • Page 21: Installation Sheet

    INSTALLATION SHEET INSTALLATION SHEET IVO SMART AC in common plus Slave + main output 1 charger start service service 1 main output 1 common min jumper selection + Slave diode compensation 0.6V RS 232 digital jack: temp. smart/standard/remote gel/wet type sensor analogue jack: forced to float...
  • Page 22: Mastervolt

    AC in common plus Slave + main output 1 charger start service service 1 Charger Control Charger Control Charger Control float float Inverter Control Charger Control Charger Output failure absorption absorption failure float failure absorption float on - bulk charge current output on - bulk charge bulk...
  • Page 24: Mastervolt

    MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands Tel.: +31-20-3422100 Fax: +31-20-6971006...

This manual is also suitable for:

Ivo smart 12/50-2

Table of Contents