TCP/IP based Ethernet. Besides, NPort 5450-T and NPort 5450I-T are designed to use in wide temperature environment. NPort 5400 Series is a Moxa Green Product. Moxa’s Green Products satisfy the RoHS directive of the European Parliament, and accordingly, do not...
Page 4
NPort 5450-T/5450I-T Reset Button—Press the Reset button continuously for 5 sec to load factory defaults: Use a pointed object, such as a straightened paper clip or toothpick, to press the reset button. This will cause the Ready LED to blink on and off. The factory defaults will be loaded once the Ready LED stops blinking (after about 5 seconds).
Selects the option listed on the LCM panel’s second line. Detailed LCM Panel Operating instructions can be found on the CD-ROM in the “NPort 5400 Series User’s Manual.” Hardware Installation Procedure STEP 1: After removing NPort 5400 from the box, the first thing you should do is attach the power adaptor.
To view detailed information about NPort Administration Suite, click on the Documents button, and then select “NPort 5400 Series User’s Manual” to open the pdf version of this user’s guide. Pin Assignments and Cable Wiring DB9 Male Port Pinouts Pin assignments apply to NPort 5410 (RS-232 only), 5450, and 5450I.
Page 7
DB9 Wiring-NPort 5410/5450/5450I DB9 Female to DB9 Male DB9 Female to DB25 Male Terminal Block Wiring- NPort 5430/5430I - 7 -...
Environmental Specifications Power requirements Input Voltage 12 to 48VDC Power Consumption: NPort 5410 350 mA @ 12 V, 190 mA @ 24 V NPort 5430 320 mA @ 12 V, 175 mA @ 24 V NPort 5430I 530 mA @ 12 V, 280 mA @ 24 V NPort 5450 350 mA @ 12 V, 190 mA @ 24 V NPort 5450I...