Disposal - Hilti GX 3-ME User Manual

Hide thumbs Also See for GX 3-ME:
Table of Contents

Advertisement

Malfunction
No fastener is driven.
The fastening tool is hot and
doesn't work even after a
break.
No fastener is driven (or
driven only intermittently).
A fastener cannot be
removed from the fastener
guide.

13 Disposal

Most of the materials from which Hilti tools and appliances are manufactured can be recycled. The
materials must be correctly separated before they can be recycled. In many countries, your old tools,
machines or appliances can be returned to Hilti for recycling. Ask Hilti Service or your Hilti representative
for further information.
14 Manufacturer's warranty
▶ Please contact your local Hilti representative if you have questions about the warranty conditions.
15 FCC statement (applicable in US) / IC statement (applicable in Canada)
This device complies with Part 15 of the FCC Rules and RSS-210 of IC. Operation is subject to the following
two conditions:
1. This device shall cause no harmful interference.
2. This device must accept any interference received, including interference that may cause undesired
operation.
12
Possible cause
Gas can is empty.
LED 1 lights red
Air in the gas lines
Foreign object in the area of the
fastener guide
The fastening tool is too hot.
Electronic fault.
The fastener driving rate was well
above 1,200 fastenings per hour.
Ambient conditions are outside the
permissible range.
The gas can temperature is outside
the permissible range.
Gas bubbles have formed in the
gas regulating system.
The tool was not lifted completely
away from the surface after driving
a fastener.
A fastener has jammed in the fas-
tener guide.
Action to be taken
▶ Check the status of the gas can.
→ page 8
▶ Check the status of the gas can.
→ page 8
▶ Press the setting tool three
times in position without pulling
the trigger.
▶ Remove foreign objects and
nails from the area around the
fastener guide. → page 9
▶ Allow the fastening tool to cool
down.
▶ Remove the gas can and then
reinsert it.
If the problem
persists, use a new gas can.
▶ Allow the fastening tool to cool
down.
▶ Make sure that the permissible
ranges, in accordance with the
technical data, are observed.
▶ Make sure that the permissible
ranges, in accordance with the
technical data, are observed.
▶ Remove the gas can and then
reinsert it.
▶ Lift the fastening tool completely
away from the working surface
after driving a fastener.
▶ Release the jammed fastener.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx 3

Table of Contents