Air Conditioning
SkyStar
SkyStar ECM
Cassette Fan Coil Units
www.eurovent-certification.com
Quality management systems
ISO 9001 – Cert. n° 0545/5
www.certiflash.com

Advertisement

Table of Contents
loading

Summary of Contents for Sabiana SkyStar

  • Page 1 Air Conditioning SkyStar SkyStar ECM Cassette Fan Coil Units www.eurovent-certification.com Quality management systems ISO 9001 – Cert. n° 0545/5 www.certiflash.com...
  • Page 2: Table Of Contents

    Page 53 • Components of the casing e Valve kit Page 54 Sabiana take part to the Eurovent program of fan coil performance certification. The official figures are published in the web site www.eurovent-certification.com and in the web site www.certiflash.com.
  • Page 3: Skystar

    Innovating and beautiful design, seven different sizes, high control flexibility, easy maintenance: the new SkyStar chilled water cassette is the result of an extended technical and design development aimed at achieving the highest level in terms of performance, silent operation and control possibilities.
  • Page 4: Main Components

    SkyStar Main components INTAKE GRID AND DISTRIBUTION OF THE AIR Intake grids, frame and adjustable air distribution louvers on each side, made from ABS. HTA version : white ABS, RAL 9003 HTB version : with intake grid, frame and louvers, choice of one colour only...
  • Page 5: Eurovent Certifications

    EUROVENT Certification Technical features www.eurovent-certification.com www.certiflash.com 2 pipe units. The following standard rating conditions are used: COOLING HEATING Entering air temperature: + 27°C d.b., + 19°C w.b. Entering air temperature: + 20°C Water temperature: + 7/12°C Water temperature: + 50°C water flow rate as for the cooling conditions MODEL SK 02...
  • Page 6: Emissions

    SkyStar Emission Cooling emission of 1 battery units (2 pipe installation) Entering air temperature: +27°C d.b. +19°C w.b. EWT 5 - LWT 10°C EWT 7 - LWT 12°C EWT 9 - LWT 14°C EWT 12 - LWT 17°C Model Speed...
  • Page 7 Emission of 4 pipe units SkyStar with standard cooling battery Cooling emission of 2 battery units (4 pipe installation) Entering air temperature: +27°C d.b. +19°C w.b. EWT 5 - LWT 10°C EWT 7 - LWT 12°C EWT 9 - LWT 14°C EWT 12 - LWT 17°C...
  • Page 8 SkyStar Emission of 4 pipe units with enhanced cooling battery Cooling emission of 2 battery units (4 pipe installation) Entering air temperature: +27°C d.b. +19°C w.b. EWT 5 - LWT 10°C EWT 7 - LWT 12°C EWT 9 - LWT 14°C EWT 12 - LWT 17°C...
  • Page 9: Water Side Pressure Drop

    SkyStar Water side pressure drop 2 pipe installation Pressure drop for mean water temperature of 10°C, for different temperatures multiply the pressure drop figure by the K correction factors in the table. °C 0,94 0,90 0,86 0,82 0,78 0,74 0,70...
  • Page 10: Dimensions And Weights

    SkyStar Dimensions and weights SK 02-04 / SK 12-14 / SK 22-24-26 / SK 32-34-36 (Version 600 x 600) 2 pipe units - 3. Flow, heating/cooling 1/2” - 4. Return, heating/cooling 1/2” 4 pipe units - 1. Flow, heating 1/2”...
  • Page 11 SkyStar Dimensions and weights SK 42-44 / SK 52-54-56 / SK 62-64-66 (Version 800 x 800) 2 pipe units - 3. Flow, heating/cooling 3/4” - 4. Return, heating/cooling 3/4” 4 pipe units - 1. Flow, heating 1/2” - 2. Return, heating 1/2”...
  • Page 12: Air Throw

    SkyStar Air throw The air throw indicated in the tables must only be considered the maximum value, as it may change significantly in relation to the dimensions of the room in which the appliance is installed and the positioning of the furniture in the room.
  • Page 13: Fresh Air Supply E Air Distribution

    SkyStar Fresh air supply - Fresh air connection The cassette is fitted FRESH AIR INLET with inlets for fresh air to be mixed with return air inside the unit (Fig. 3). The fresh air flow is limited to 20% of the total fan coil air flow at medium speed and 100 m /h for each treated air inlet.
  • Page 14: Accessories

    Units with remote electric board On request the Skystar cassettes are available with electric control panel reachable from below and with the electric board that can be placed in a remote position. In this case the units are supplied with an electronic connecting control panel, fitted to the bottom side on the 4 smallest sizes and to the lateral side on the 3 biggest sizes.
  • Page 15 SkyStar Accessories ON-OFF valves with thermoelectric actuator ALVE WITH ICROMETRIC OCKSHIELD ALVE 3 ways 2 ways ALVE WITH IMPLIFIED 3 ways 2 ways Technical data: Valves characteristics Rated pressure: 16 bar 2 way valves 3 way valves Battery Model ¨p ¨p...
  • Page 16: Crystall Electrostatic Filter

    SkyStar CRYSTALL Introduction Cassette SkyStar can be equipped with the innovative plate type electrostatic filter, Crystall, combining air treatment and purifying in a single product. The electronic filter is patented and certified according to Standard UNI 11254. Dimensions SK 0 / 1 / 2 / 3...
  • Page 17 EN 1379:2008). Moreover, according to the UNI 10339rev, air recirculated by the Crystall appliance can be considered as fresh air, to be added to the minimum requirements (0,5 ls/m2). Purifying the air with the Sabiana Crystall appliance also entails no reduction of living room space, as the dimensions of the fan convector are practically unchanged (just 3 cm higher).
  • Page 18 SkyStar CRYSTALL The quantity and quality of recirculated air and outdoor air to be added is better specified in the prescriptive and performance approach in Standards UNI EN 13779:2008 and soon to be released UNI 10339rev according to the following simplified tables.
  • Page 19: Construction Features

    All electrical connections are made during production. The installation of the SkyStar Sabiana cassette fan coil unit incorporating the Crystall electronic filter is therefore similar to that of a normal unit: the only difference is the installation height, for which the filter dimensions must taken into account.
  • Page 20: Wall Electronic Controls

    Wall electronic controls If using the Skystar Cassette fan coils with electronic controllers, the voltage values at the autotransformer terminals must be kept in consideration (transformer return voltages). These values may reach 500 Vac. DENTIFICATION MO-3V 9060160 • Manual 3 speed switch.
  • Page 21 SkyStar Wall electronic controls DENTIFICATION • ON-OFF switch. TMO-T-AU 9060164 • Manual or automatic 3 speed switch. • Summer/Winter switch. • Electronic room thermostat for fan control (ON-OFF). • Electronic room thermostat for valve control (ON-OFF) (the fan keeps working).
  • Page 22 SkyStar Speed switches DENTIFICATION SEL-S 9079110 • Speed switch (Slave). • It allows to control up to 8 units with only one centralized wall control (1 speed switch for each unit). • For controls CR-T, TMO-T, TMO-T-AU and TMO-503-SV2. DENTIFICATION...
  • Page 23 SkyStar Control functions Electrical diagrams are shown on the installation, use and maintenance manual 9060174 9060165 TMO-DI TMO-503-SV2 9060173 TMO-T-AU 9060164 TMO-T 9060161 CR-T 9066330 MO-3V 9060160...
  • Page 24: Freesabiana Wireless Control System

    SkyStar FreeSabiana wireless control system FreeSabiana Free Sabiana is an innovative, fully wireless, electronic system for use with fan coil units, based on radio communication. This technology provides installation flexibility and a more accurate measurement of the room temperature. The probe can be moved until the most suitable position is found, without the worry of changes in the environment layout and of its furniture and also without mounting it on a wall.
  • Page 25 SkyStar FreeSabiana wireless control system Main features of the remote control The control enables: ❍ Fan coil on/off switching ❍ Fan speed selection (high - medium - low - automatic) ❍ Summer/winter operation selection ❍ Valve on/off ❍ Real time clock setting ❍...
  • Page 26: Controls For Sk-Mb Versions

    SkyStar Controls for SK–MB versions All the SkyStar units can be supplied in MB version. This version includes a wide range of controls, including the infra-red remote control, which allows managing one single unit or several units by using the Modbus RTU - RS 485 communication protocol.
  • Page 27: Electric Heater Sk-E

    Electric heater SK-E The SkyStar 2 pipe models are available with electric heater that is controlled in place of the heating battery valve. The electric heater is controlled in place of the hot water valve and not as integration to it.
  • Page 28: Skystar Ecm

    The SkyStar ECM series uses an innovative brushless synchronous permanent magnet electric motor controlled by an inverter card that is directly installed on the unit. The air flow can be varied continuously with a 1-10 V signal from Sabiana controls or by independent contollers (programmable controllers with a 1-10 V output).
  • Page 29: Main Components

    SkyStar ECM SkyStar SkyStar ECM Main components INTAKE GRID AND DISTRIBUTION OF THE AIR Intake grids, frame and adjustable air distribution louvers on each side, made from ABS. HTA version : white ABS, RAL 9003 HTB version : with intake grid, frame and louvers, choice of one colour only...
  • Page 30: Eurovent Certifications

    SkyStar ECM SkyStar SkyStar ECM EUROVENT Certification www.eurovent-certification.com www.certiflash.com Technical features 2 pipe units. The following standard rating conditions are used: COOLING HEATING Entering air temperature: + 27°C d.b., + 19°C w.b. Entering air temperature: + 20°C Water temperature: + 7/12°C Water temperature: + 50°C...
  • Page 31: Emissions

    SkyStar ECM SkyStar SkyStar ECM Emission Cooling emission of 1 battery units (2 pipe installation) Entering air temperature: +27°C d.b. +19°C w.b. EWT 5 - LWT 10°C EWT 7 - LWT 12°C EWT 9 - LWT 14°C EWT 12 - LWT 17°C...
  • Page 32 SkyStar ECM SkyStar SkyStar ECM Emission of 4 pipe units with standard and enhanced cooling battery Cooling emission of 2 battery units (4 pipe installation) Entering air temperature: +27°C d.b. +19°C w.b. EWT 5 - LWT 10°C EWT 7 - LWT 12°C EWT 9 - LWT 14°C...
  • Page 33: Water Side Pressure Drop

    SkyStar ECM SkyStar SkyStar ECM Water side pressure drop 2 pipe installation Pressure drop for mean water temperature of 10°C, for different temperatures multiply the pressure drop figure by the K correction factors in the table. °C 0,94 0,90 0,86...
  • Page 34: Dimensions And Weights

    SkyStar ECM SkyStar SkyStar ECM Dimensions and weights SK 12-14 / SK 22-26 / SK 32-36 (Version 600 x 600) 2 pipe units - 3. Flow, heating/cooling 1/2” - 4. Return, heating/cooling 1/2” 4 pipe units - 1. Flow, heating 1/2”...
  • Page 35 SkyStar ECM SkyStar ECM Dimensions and weights SK 42-44 / SK 52-56 (Version 800 x 800) 2 pipe units - 3. Flow, heating/cooling 3/4” - 4. Return, heating/cooling 3/4” 4 pipe units - 1. Flow, heating 1/2” - 2. Return, heating 1/2”...
  • Page 36: Air Throw

    SkyStar ECM SkyStar SkyStar ECM Air throw The air throw indicated in the tables must only be considered the maximum value, as it may change significantly in relation to the dimensions of the room in which the appliance is installed and the positioning of the furniture in the room.
  • Page 37: Accessories

    SkyStar ECM SkyStar SkyStar ECM Accessories Fresh air connection See page 13. DENTIFICATION 6078005 Air distribution connection See page 13. DENTIFICATION The diameter of the fitting CDA 600 9079232 is 150 mm for SK 1 - 2 - 3 CDA 800 9079233 and 180 mm for SK 4 - 5.
  • Page 38 SkyStar ECM SkyStar SkyStar ECM ON-OFF valves with thermoelectric actuator ALVE WITH ICROMETRIC OCKSHIELD ALVE 3 ways 2 ways ALVE WITH IMPLIFIED 3 ways 2 ways Technical data: Valves characteristics Rated pressure: 16 bar 2 way valves 3 way valves Battery ¨p...
  • Page 39: Sk−Ecm Configuration

    SkyStar ECM SkyStar SkyStar ECM SK–ECM configuration For this cassette configuration, the 1-10 Vdc signal, which controls the inverter, must be supplied by a controller with the following signal specifications: • Impedance < 100 1; • Maximum speed 10Vdc; • Fan OFF with V < 0.9Vdc.
  • Page 40: Wall Electronic Controls

    SkyStar ECM SkyStar SkyStar ECM Wall electronic controls DENTIFICATION CR-T-ECM 9066342 The control must always be connected with UPM-ECM power unit (fitted on the unit) or with UPS-ECM power unit (not fitted on the unit). • It allows to control up to 16 units (one power unit for each unit).
  • Page 41 SkyStar ECM SkyStar SkyStar ECM Wall electronic control accessories NTC low temperature cut-out thermostat To be fitted between the coil fins. When connecting the control, the NTC probe cable must be separated from the power supply wires. To be used with CR-T-ECM and CR-DI-ECM controls.
  • Page 42: Controls For Sk-Ecm-Mb Versions

    SkyStar ECM Controls for SK–ECM–MB versions All the SkyStar ECM units can be supplied in MB version. This version includes a wide range of controls, including the infra-red remote control, which allows managing one single unit or several units by using the Modbus RTU - RS 485 communication protocol.
  • Page 43: Skystar / Skystar Ecm

    SkyStar ECM SkyStar SkyStar / SkyStar ECM MB controls MB electronic board The MB electronic board, mounted as per standard on the SK–MB and SK–ECM–MB versions, is set to carry out different functions and adjustment modes, in order to meet the installation requirements.
  • Page 44: T-Mb Wall Mounted Control

    SkyStar ECM SkyStar SkyStar / SkyStar ECM MB controls T-MB wall control ESCRIPTION DENTIFICATION Wall control (to be used with SK–MB and SK–ECM–MB version only) T-MB 9066331 Wall control with display that allows controlling one or more units in Master/Slave mode.
  • Page 45: Rt03 Infra-Red Remote Control

    SkyStar ECM SkyStar SkyStar / SkyStar ECM MB controls RT03 infra-red remote control ESCRIPTION DENTIFICATION RT03 infra-red remote control with receiver supplied with separate packaging RCS-RT03 9079117 (to be used with SK–MB and SK–ECM–MB version only) Receiver for RT03 infra-red remote control supplied with separate packaging 9079116 (to be used with SK–MB and SK–ECM–MB version only)
  • Page 46 MB controls A group of SkyStar MB can be connected via a serial link and can consequently be managed at the same time by just one T-MB wall control or RT03 infra-red remote control. Using the special jumper present on the MB board, one unit must be configured as the master, and all the others as slaves.
  • Page 47: Psm-Di Multifunction Control

    SkyStar ECM SkyStar SkyStar / SkyStar ECM MB controls PSM-DI multifunction control ESCRIPTION DENTIFICATION Multifunction control (to be used with SK–MB and SK–ECM–MB version only) PSM-DI 3021293 Another option available for the serial communication between the units is the possibility to connect up to 60 Cassette units in series and manage them with just one wall mounted PSM-DI controller.
  • Page 48: Sabianet Management System

    9079118 (to be used with SK–MB and SK–ECM–MB version only) Sabianet is a centralised control system for networks of Sabiana MB fan coils, based on software that runs on LINUX™. The Sabianet software offers a practical and economical solution for managing the units, with the simple click of the mouse.
  • Page 49 SkyStar ECM SkyStar SkyStar / SkyStar ECM Management system for a network of fan coils Displaying a unit “MONITORING” S CREEN shows the units that are connected to the network and scanned by the program. The icon of the terminal unit...
  • Page 50: Psm-Di And Sabianet Accessories

    60 units max. ( Connection Cassette Cassette Cassette of a Cassette SkyStar SK–MB unit unit unit or SK–ECM–MB network MC2 Jumper to be closed. End of network. RS 485 ) In the event...
  • Page 51: Skystar Mct

    The cover cabinet fits perfectly to the air intake and outlet diffuser, maintaining the appealing design that defines the SkyStar series. The water fittings can be turned to point upwards. The MCT series includes 7 models, with an installation height of up to 5 m, thanks to the highly flexible adjustment of the air distribution louvers.
  • Page 52: Dimensions And Weights

    SkyStar MCT SkyStar SkyStar MCT Dimensions and Weights SK 02-MCT / SK 12-MCT / SK 22-MCT / SK 32-MCT Casing code: 9079240 Casing weight: 5 kg (7,5 kg with the packaging) SK 42-MCT / SK 52-MCT / SK 62-MCT Casing code:...
  • Page 53: Assembly Diagram

    SkyStar MCT SkyStar SkyStar MCT Assembly diagram...
  • Page 54: Components Of The Casing E Valve Kit

    For the specifications of the valves, see page 15. The descriptions and illustrations provided in this publication are not binding: Sabiana reserves the right, whilst maintaining the essential characteristics of the types described and illustrated, to make, at any time, without the requirement to promptly update this piece of literature, any changes that it considers useful for the purpose of improvement or for any other manufacturing or commercial requirements.
  • Page 55 MD-600 Diffuser...
  • Page 56 Air Conditioning SkyStar - SkyStar ECM Cassette Fan Coil Units Sabiana s.p.a. via Piave, 53 20011 Corbetta Milano Italy phone +39.02.97203.1 r.a. / +39.02.97270429 / +39.02.97270576 • • • • • fax +39.02.9777282 / +39.02.9772820 www.sabiana.it info@sabiana.it • •...