Spare parts Foreword As manufacturer of gas heating appliances, DRU develops and produces products to meet the highest possible quality, performance and safety requirements. As a result of which the user is able to enjoy using your appliance for years to come.
This system can be installed through the wall or through the roof. The appliance is built in a chimney breast. For this, DRU has a number of chimney breasts in its range. In order to reach a proper heat discharge, the chimney breast must be ventilated. DRU is able to supply various ventilation elements.
Annex 1 / Table 4 specifi es the components you should have once everything has been unpacked. ➠ Contact DRU Service if after unpacking the appliance you do not have all the components; ➠ Dispose of the packaging in an appropriate manner.
If necessary, you can also use an existing discharge channel (see section 6.5.4). N.B. - Only use the concentric system supplied by DRU Fig. 3 (Ø100 / Ø150 mm). This system was tested in com- bination with the appliance; DRU cannot guarantee a proper and safe operation of other systems and cannot accept liability for these systems;...
Page 7
8 0 - A P O L L O I N S T R U C T I O N F O R I N S TA L L AT I O N wall. Then, the rosette is mounted on the intermediate plate. ➠...
Page 8
80 - P O L L O I N S T R U C T I O N F O R I N S TA L L AT I O N Example 2 1) 3 bends 2) 4 meters horizontal 3) 10 meters vertical/sloping →...
- protecting the gas control block and hoses from cement and plaster. !Tip The vents should preferably be created in both sides of the chimney breast: you could use DRU ventilation elements. ➠ Check that the concentric system has been installed correctly;...
8 0 - A P O L L O I N S T R U C T I O N F O R I N S TA L L AT I O N 6.8.3 Primary aeration of the burners Caution Adjusting the primary aeration only applies to appliances used in Belgium. When the tray surrounding the burners is removed, you can see the throttle rings (Pa and Pb) that are mounted on the pipes that are fi...
Page 12
80 - P O L L O I N S T R U C T I O N F O R I N S TA L L AT I O N Photo 4a Photo 4b Photo 5 Photo 6a 95901101UK Install_UK.indd 12 95901101UK Install_UK.indd 12 23-01-2009 09:38:40 23-01-2009 09:38:40...
Page 13
8 0 - A P O L L O I N S T R U C T I O N F O R I N S TA L L AT I O N Photo 6b Photo 6c Photo 6d Photo 6e Photo 6f Photo 6g Photo 6h...
Page 14
80 - P O L L O I N S T R U C T I O N F O R I N S TA L L AT I O N Photo 7a Photo 10a Photo 10b Photo 7b Photo 10c Photo 10d Photo 8 Photo 9...
80 - P O L L O I N S T R U C T I O N F O R I N S TA L L AT I O N !N.B. - Make sure you hold the upper handgrip fi rmly. If you let go of the handgrip then the glass frame could fall inwards and cause severe damage to both the glass and the appliance;...
Page 17
8 0 - A P O L L O I N S T R U C T I O N F O R I N S TA L L AT I O N Photo 13 Photo 14 ➠ Place the receiver in the control box: Photo 14 - Position the receiver as shown in ➠...
80 - P O L L O I N S T R U C T I O N F O R I N S TA L L AT I O N Final inspection To ensure the appliance is working correctly and safely, check the following before use: 8.1 Gastightness N.B.
8 0 - A P O L L O I N S T R U C T I O N F O R I N S TA L L AT I O N Maintenance The appliance should be inspected, cleaned and if necessary repaired by a qualifi ed installer with professional expe- rience of decorative gas fi...
80 - P O L L O I N S T R U C T I O N F O R I N S TA L L AT I O N 11. Troubleshooting A number of faults which could occur, their possible causes and solutions are shown in the table below: Table 3: Troubleshooting Problem Possible cause...
Page 21
8 0 - A P O L L O I N S T R U C T I O N F O R I N S TA L L AT I O N G. Pilot burner is burning but 1. Thermocouple is not working 1.1 Measure the voltage with a digital multi- the magnetic valve closes meter, set to mV range, by connecting the...
923001 Penlight battery (AA type) 923100 Pressure coupling 15 mm x G3/8” 149234 Annex 2 Technical data The technical data for the Apollo 80 are given in the table below. Table 5: Technical data Type C11/C31 Gas type Burner pressure...
Page 23
8 0 - A P O L L O I N S T R U C T I O N F O R I N S TA L L AT I O N Notes ........................................... . .
Page 24
80 - P O L L O I N S T R U C T I O N F O R I N S TA L L AT I O N DRU Verwarming B.V. The Netherlands Postbus 1021, NL-6920 BA Duiven Ratio 8, NL-6921 RW Duiven 95901101UK Install_UK.indd 24...
Need help?
Do you have a question about the Apollo 80 and is the answer not in the manual?