PRODUCT SPECIFICATIONS
ENGINE
Engine Type ...................................................... 212cc OHV
Spark Plug ................................. NGK BP6ES or equivalent
Engine Lubricant Volume................... approximately 20 oz.
Fuel Volume ................................................................ 4 gal.
KNOW YOUR GENERATOR
See Figure 1.
The safe use of this product requires an understanding of the
information on the product and in this operator's manual as
well as a knowledge of the project you are attempting. Before
use of this product, familiarize yourself with all operating
features and safety rules.
AC CIRCUIT BREAKERS
The circuit breakers are provided to protect the generator
against electrical overload. The circuit breaker may be reset
by pressing the circuit breaker reset button.
AIR FILTER
The air filter helps to limit the amount of dirt and dust drawn
into the unit during operation.
ENGINE SWITCH/FUEL VALVE/
CHOKE LEVER
The engine switch/fuel valve/choke lever is used when start-
ing, stopping, and running the engine.
FUEL TANK
The fuel tank has a capacity of 4 gallons.

FEATURES

GENERATOR
Rated Voltage .............................................................120 V
Rated Amps ................................................................. 30 A
Rated Output .......................................................... 3600 W
Starting Watts ......................................................... 4500 W
Rated Frequency ....................................................... 60 Hz
GROUND TERMINAL
The ground terminal is used to assist in properly grounding
the generator to help protect against electrical shock. Consult
with a qualified local electrician for grounding requirements
in your area.
LOW OIL SHUT DOWN PROTECTOR
The low oil sensor causes the engine to stop if the level of
lubricant in the crankcase is insufficient.
OIL CAP/DIPSTICK
Remove the oil fill cap to check and add lubricant to the
generator when necessary.
OIL DRAIN PLUG
When changing the engine lubricant, unscrew and remove
the oil drain plug to allow old engine lubricant to be drained.
RECEPTACLES
Your generator has the following single phase, 60 Hz out-
lets: two 120 Volt AC, 20 Amp duplex receptacles and one
120 Volt AC 30 Amp RV receptacle. These can be used for
operating appropriate appliances, electrical lighting, tools,
and motor loads.
RECOIL STARTER GRIP
The recoil starter grip is used to start the generator's engine.