NA-806D Hardware Installation Guide For service person only...
Page 2
Disclaimers The information in this manual has been carefully checked and is believed to be accurate. AXIOMTEK Co., Ltd. assumes no responsibility for any infringements of patents or other rights of third parties, which may result from its use. AXIOMTEK assumes no responsibility for any inaccuracies that may be contained in this document.
Page 3
Safety Approvals CE Marking FCC Class A FCC Compliance This equipment has been tested and complies with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Most electronic components are sensitive to static electrical charge. 2. Disconnect the power cords from the NA-806D before making any installation. Be sure both the system and the external devices are turned OFF. Sudden surge of power could ruin sensitive components. Make sure the NA-806D is properly grounded.
Table of Contents Disclaimers................... ii FCC Compliance................. iii C h a p t e r 1 ..................1 General Description............1 Standard Features ............3 System Specifications..........3 1.3.1 Hardware............3 Dimensions ..............5 Front Panel Outlets.............6 Rear Panel Outlets .............8 C h a p t e r 2 ..................9 Preinstallation Checklist ..........9 Setting up the appliance ..........9 2.2.1...
Page 6
Standard CMOS Setup ..........17 Advanced BIOS Features........20 Advanced Chipset Features ........23 Integrated Peripherals ..........27 Power Management Setup ........29 PNP/PCI Configuration..........31 PC Health Status ............. 33 3.10 Load Optimized Defaults ......... 34 3.11 Set Supervisor/User Password........ 35 3.12 Save &...
General Description NA-806D Front View (1U Rack mount type) The NA-806D server is designed for network software solution providers those have data secure, voice over IP, video streaming, network bandwidth controller and another networking appliance requirements across this stable and reliable multiple LAN device.
Page 8
It also can support LAN by-pass features which can isolate the defective segments. NA-806D has pretty good enclosure management interface to be implemented in the factory default. It can support P.O.S.T (Power On Self Test) feature through hyper-terminal by console port.
NA-806D Hardware Installation Guide Standard Features Ultra Low Voltage Intel® Celeron® M processor, low power consumption and high computing power Supports four Ethernet ports Supports LAN bypass and BIOS redirected to COM port features Completely fanless in 1U type of rack mount or wall mount system design.
Page 10
NA-806B / C Hardware Installation Guide 4 x RJ-45 ports 1 x Console port 1 x VGA port 2 x USB ports 1 x KB/MS connector 1 X DC-in power connector Processor: Intel 479-pin socket for Celeron M / Pentium M FSB400 processor; up to 2.1GHz BIOS: Award 4MB Flash BIOS Plug &...
NA-806B / C Hardware Installation Guide 1.5 Front Panel Outlets Located at the front panel of the NA-806D server are the I/O outlets for connections of serial and Ethernet interface-supported devices. The NA-806D Server Front Panel Console Port LAN link / transfer rate Console port –...
Page 13
NA-806D Hardware Installation Guide Indications of Front Panel Power on LED 1. System and power on HDD LED Link/Active LED (single color) 1. The green LED is on when the HD has connection normally 2. The LED flashes when there is transmit or receive activity III.
NA-806B / C Hardware Installation Guide Rear Panel Outlets Located at the rear panel of the NA-806D are I/O outlets for connections of serial and Ethernet interface-supported devices. . K/B & M/S Console Port VGA Port 12V, 5A LAN Ports...
2.2.1 Removing and Replacing the Top Cover To gain access into the internal components of the NA-806D, you must follow the instructions given below to remove the top cover. Please release the screws of lower case and left with right side first.
To accommodate the fast transfer rate of Ultra ATA 66/100/133, a cable (with 44 pin connectors on both ends) is necessary when installing Ultra DMA/66/100/133 drives. The NA-806D, on this aspect, can support 2.5” IDE hard drive and DOM (Disk on Module) deployment. It is through the IDE Connector (CN15, CN16) 2.2.4...
NA-806D Hardware Installation Guide Jumper Default Setting Jumper Setting PLRS1 Power LED: Normal Mode Short 2-3 HDD LED: Normal Mode Short 4-5 Reset Switch: Normal Mode Short 6-7 External Speaker : Normal Mode Short 8-11 CMOS Clear Jumper: Normal Mode...
Page 18
NA-806B / C Hardware Installation Guide PIN NO. DESCRIPTION Data Carrier Delect(DCD) Data Set Ready(DSR) Receive Date(RXD) Request to Send(RTS) Transmit Data(TXD) Clear to Send(CTS) Data Terminal Ready (DTR) Ring Indicator(RI) Award BIOS Utility...
2.2.9 Enabling LAN by-pass feature What’s the LAN by-pass means for NA-806D series? That doesn’t have any down time in network connections for other specify two network segments (LAN1 and LAN2) while it has any fetal errors for this device.
NA-806B / C Hardware Installation Guide C h a p t e r 3 Award BIOS Utility Chapter 3 describes the different settings available in the Award BIOS that comes with the SBC8A806. Also contained here are instructions on how to set up the BIOS configuration.
NA-806D Hardware Installation Guide The section below the setup items of the Main Menu displays the control keys for this menu. Another section located at the bottom of the Main Menu, just below the control keys section, displays information on the currently highlighted item in the list.
Page 24
NA-806B / C Hardware Installation Guide however, if you change your system hardware configurations, the onboard battery fails, or the configuration stored in the CMOS memory was lost or damaged. At the bottom of the menu are the control keys for use on this menu. If you need any help in each item field, you can press the <F1>...
Page 25
NA-806D Hardware Installation Guide The day of week, from Sun to Sat, determined by the BIOS, is read only The date, from 1 to 31 (or the maximum allowed in date the month), can key in the numerical / function key The month, Jan through Dec.
NA-806B / C Hardware Installation Guide Halt On This field determines whether the system will halt if an error is detected during power up. The system boot will halt on any error No errors detected. (default) Whenever the BIOS detects a non-fatal All errors error, the system will stop and you will be prompted.
Page 27
NA-806D Hardware Installation Guide Virus Warning This item protects the boot sector and partition table of your hard disk against accidental modifications. If an attempt is made, the BIOS will halt the system and display a warning message. If this occurs, you can either allow the operation to continue or run an anti-virus program to locate and remove the problem.
Page 28
NA-806B / C Hardware Installation Guide The system will not boot and access to Setup System will be denied if the incorrect password is entered at the prompt. The system will boot, but access to Setup will Setup be denied if the correct password is not entered at the prompt.
NA-806D Hardware Installation Guide Advanced Chipset Features Since the features in this section are related to the chipset on the CPU board and are completely optimized, you are not recommended to change the default settings in this setup table unless you are well oriented with the chipset features.
Page 30
NA-806B / C Hardware Installation Guide Award BIOS Utility...
Page 31
NA-806D Hardware Installation Guide Console Redirection This item allows you to enable or disable the BIOS boot up and redirect to console port feature. The choice: Enable, Disable Baud Rate This item allows you to setup the data transfer rate for the console port.
Page 32
NA-806B / C Hardware Installation Guide incomplete and the DRAM may fail to retain data. Fast gives faster performance; and Slow gives more stable performance. This field applies only when synchronous DRAM is installed in the system. The Choice: 2, 3. System BIOS Cacheable The ROM BIOS can be mapping to the addresses as F0000h to FFFFFh pass through buffer cache;...
NA-806D Hardware Installation Guide DRAM Data Integrity Mode The ECC( Error Checking and Correction)mode adopted extra 72-bit to check the data integrity. It can correct one bit error. We can make the system stability and reliability by this way accordingly. If you doesn’t have ECC memory deployment, you can set the value to be Non-ECC.
Page 34
NA-806B / C Hardware Installation Guide IDE Primary/Secondary Master/Slave PIO The four IDE PIO (Programmed Input/Output) fields let you set a PIO mode (0-4) for each of the four IDE devices that the onboard IDE interface supports. Modes 0 through 4 provide successively increased performance.
NA-806D Hardware Installation Guide Onboard Serial Port 2 Select an address and corresponding interrupt for the first and second serial ports. The choice: 3F8/IRQ4, 2E8/IRQ3, 3E8/IRQ4, 2F8/IRQ3, Disabled, Auto. Power Management Setup The Power Management Setup allows you to save energy of your system effectively.
Page 36
NA-806B / C Hardware Installation Guide Video Off Method In suspending, this item allows you to select the CRT closed method under APM mode. The choice: Blank Screen, V/H SYNC+Blank, DPMS Video Off In Suspend In suspending, this item allows you to select if you want to close the CRT under APM mode.
NA-806D Hardware Installation Guide PNP/PCI Configuration This section describes configuring the PCI bus system. PCI, or Personal Computer Interconnect, is a system which allows I/O devices to operate at speeds nearing the speed the CPU itself uses when communicating with its own special components.
Page 38
NA-806B / C Hardware Installation Guide using a Plug and Play operating system such as Windows®98. The options available are Auto and Manual. IRQ Resources When resources are controlled manually, assign each system interrupt a type, depending on the type of device using the interrupt.
NA-806D Hardware Installation Guide PC Health Status This option configures the PCI bus system. All PCI bus systems on the system use INT#, thus all installed PCI cards must be set to this value. Current System Temp. Show you the current system temperature.
NA-806B / C Hardware Installation Guide 3.10 Load Optimized Defaults This option allows you to load the default values to your system configuration. These default settings are optimal and enable all high performance features. To load SETUP defaults value to CMOS SRAM, enter “Y”. If not, enter “N”. Award BIOS Utility...
NA-806D Hardware Installation Guide 3.11 Set Supervisor/User Password You can set either supervisor or user password, or both of then. The differences between are: Award BIOS Utility...
Page 42
NA-806B / C Hardware Installation Guide supervisor password: can enter and change the options of the setup menus. user password: just can enter but do not have the right to change the options of the setup menus. When you select this function, the following message will appear at the center of the screen to assist you in creating a password.
NA-806D Hardware Installation Guide PASSWORD DISABLED When a password is enabled, you have to type it every time you enter Setup. This prevents any unauthorized person from changing your system configuration. Additionally when a password is enabled, you can also require the BIOS to request a password every time the system reboots.
NA-806B / C Hardware Installation Guide 3.13 Quit Without Saving Select this option to exit the Setup utility without saving the changes you have made in this session. Typing “Y” will quit the Setup utility without saving the modifications. Typing “N” will return you to Setup utility. Award BIOS Utility...
Page 45
NA-806D Hardware Installation Guide A p p e n d i x Warning This is a class A Product. In a domestic Environment this Product may cause radio interference in which case the user may be required to take adequate measures.