Info; Lock - Denwa Communications DW-V-AXT-ANDROID User Manual

Hide thumbs Also See for DW-V-AXT-ANDROID:
Table of Contents

Advertisement

Info

7.
To view system information, press "Info" on the screen. It includes Machine number,
network address, MAC address, Software version and hardware version.

Lock

8.
Press "Lock" to configure door lock and door sensor.
 Door lock can be configure as "Positive" or "Negative". "Positive" is usually apply
for uni-direction situation, it is better to have UPS power when apply this door
type, since the door will be locked when power disaster. "Negative" allows door
be opened either forward or backward. It is perfect for emergency exit, due to
the door will be unlocked while power off. Please refer to the label specification
when connect the wire to corresponding interface on the back.
 Lock delay allows door remain "open" for certain period. The range of this
period is from 0s to 10s.
 Door sensor can be configured as "OFF", "On_Alarm" and "Off_Alarm". "OFF"
indicates disable door sensor. Whereas "On_Alarm" or "Off_Alarm" will
broadcast alarm if the door constantly "open" or "closed" over pre-set time