Landing Ledge - Viking vdsc530t Service Manual

30" electronic control dual fuel range
Hide thumbs Also See for vdsc530t:
Table of Contents

Advertisement

Service Diagnostics and Procedures–Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect gas supply and electrical power to unit
before servicing. Discharge capacitor through a resistor before attempting to service. Wires removed during
disassembly must be replaced on proper terminals to insure correct earth ground and polarization. After
servicing, reconnect electrical power and gas supply. Before placing appliance into operation, always check
for gas leaks with soapy water solution. DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.

Landing Ledge

To access control panel, light switch, gas valves and
spark module:
1.
Remove knobs and screws securing burner
and oven control bezels.
Screw
2.
Open oven door and remove screws securing
landing ledge.
Screw
3.
Lift up on control panel to disengage from
keyhole slots.
© 2010 Viking Preferred Service
WARNING
4.
Lower landing ledge and disconnect control
ribbon and oven light switch wires.
Screw
Light Switch Connection
5.
If the control board needs replacing, remove
screws securing oven control to the landing
ledge (shown below). If only removing landing
Ledge to access other components, simply
unplug the two wires to the oven light switch
and place landing ledge in a secure location.
Screw
Key hole Screw
6.
Repair/replace landing ledge as needed.
7.
Reverse procedure to reinstall.
Screw
Screw
Oven Light Switch
Control Ribbon