Outdoor Unit - Sanyo SAP–K92A Technical & Service Manual

Split system air conditioner
Hide thumbs Also See for SAP–K92A:
Table of Contents

Advertisement

2-2-2. Outdoor Unit

Outdoor Unit
SAP – C92A
Type
Compressor model
Nominal output
Compressor oil ... Amount
Coil resistance (Ambient temp. 25°C)
Type
Safety
Overload relay
devices
Operating temp.
Operating amp.(Ambient temp. 25°C)
Run capacitor
Type
Number ... Dia.
Fan motor model ... Number
No. of poles ... rpm (240 V, High)
Nominal output
Coil resistance (Ambient temp. 20°C)
Safety
Type
devices
Operating temp.
Run capacitor
Coil
Rows
Fin pitch
Face area
External Finish
W
cc
Open
°C
Close
°C
Trip in 6 to 16 sec. at 16 A
µF
VAC
mm
W
Open
°C
Close
µF
VAC
mm
2
m
10
Rotary (Hermetic)
C–R81H5Q 80682645–S
800
4GS D –T or SAY-56T ... 500
C – R : 3.38
C – S : 7.49
External (OLR A)
MRA99109–9201
150 ± 5
69 ± 11
22.5
400
Propeller
1 ... ø 370
UE6-21AH5PB-S ... 1
6 ... 780
20
WHT – BRN : 338.3
WHT – PNK : 389.7
Thermal fuse
145 ± 2
1.5
440
Aluminum plate fin / Copper tube
1
1.3
0.333
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
External (OLR T)
CS–7C115
115 ± 3
95 ± 5