Electrical Data; Electrical Characteristics - Sanyo SAP–K92A Technical & Service Manual

Split system air conditioner
Hide thumbs Also See for SAP–K92A:
Table of Contents

Advertisement

6. ELECTRICAL DATA

6-1. Electrical Characteristics

Indoor Unit
SAP – K92A
Outdoor Unit
SAP – C92A
Performance at
Rating Conditions
Full Load Conditions Running Amps.
Rating Conditions
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Indoor Unit
SAP – K122A
Outdoor Unit
SAP – C122A
Performance at
Rating Conditions
Full Load Conditions Running Amps.
Rating Conditions
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Indoor Unit
Running Amps.
A
0.17
Power Input
kW 0.034 / 0.040
A
0.17
Power Input
kW 0.034 / 0.040
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
Running Amps.
A
0.17
Power Input
kW 0.034 / 0.040
A
0.17
Power Input
kW 0.034 / 0.040
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Outdoor Air Temperature 43°C D.B.
Fan Motor
Fan Motor
220 – 240V Single phase 50Hz
/ 0.18
0.24 / 0.25
0.052 / 0.060
/ 0.18
0.24 / 0.25
0.052 / 0.060
Fan Motor
Fan Motor
220 – 240V Single phase 50Hz
/ 0.18
0.23 / 0.24
0.050 / 0.058
/ 0.18
0.23 / 0.24
0.050 / 0.058
30
Outdoor Unit
Compressor
3.49
/ 3.47
0.754 / 0.830
4.49
/ 4.27
0.964 / 0.990
Outdoor Unit
Compressor
5.40
/ 5.48
1.156 / 1.192
6.80
/ 6.78
1.476 / 1.502
Complete Unit
3.9
/
3.9
0.84
/ 0.93
4.9
/
4.7
1.05
/ 1.09
Complete Unit
5.8
/
5.9
1.24
/ 1.29
7.2
/
7.2
1.56
/ 1.60

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents