Operation of the Sterilized and Electrolyzed Mist
The Generation of the Sterilized and Electrolyzed Mist
The electrode on the electrolyzing unit is energized to generate electrolyzed water through
electrolysis of the tap water in the tank.
The electrolyzed water is turned into a nano-sized ultra fine mist using an ultrasonic transducer.
This sterilized and electrolyzed mist is then released from the mist outlet into the air, which is
stirred around the room by a clean discharge of air.
The Operation of the Sterilized and Electrolyzed Mist
The operation of the sterilized and electrolyzed mist is controlled by removing the front cover
and switching the electrolyzed water button on or off, which enables the choice of whether or
not to run the water electrolyzing operation (generation of a sterilized and electrolyzed mist.)
While the power mist is operating, the electrolyzed water button is usually on and cannot be
turned off.
Under either automatic or manual operation, the sterilized and electrolyzed mist operates in
accordance with the airflow speed of the fan motor, as shown in the chart below. The ultrasonic
transducer is run at high medium or low medium speed and when it is operating, the
electrolyzed water lamp (green) and the electrolyzed water lamp (blue) will be lit.
When the power mist is operating, the ultrasonic transducer is operated in power mode.
(Refer to the chart below.)
When the electrolyzing unit and the tank are detached (the tank-attached detection switch will be
off), the sterilized and electrolyzed mist will not operate. (The electrolyzed water lamp (green)
and the electrolyzed water lamp (blue) will be turned off.)
Airflow Speed
(Operating Status)
Manual Operation
Automatic Operation
Sterilized and
Electrolyzed Mist
Power Mist Operation
Sterilized and
Electrolyzed Mist
Low
... 0.5 seconds on, 5 seconds off – Intermittent operation of ultrasonic transducer
Storng ... 1 second on, 2 seconds off – Intermittent operation of ultrasonic transducer
Power ...1 second on, 1 second off – Intermittent operation of ultrasonic transducer
Stop
Low
(Automatic)
Low
Stop
Low
Stop
Low
Low Med
Med
Med
Low Med
Med
Low
Low
Med
Power
- 7-
ABC-VW24
High Med
High
High
High Med
Storng
Storng
High Med
High
Power