Magicsafe Ms660 - Waeco MagicSafe MS660 Installation And Operating Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 59
_MS660.book Seite 73 Montag, 2. August 2010 8:03 20

MagicSafe MS660

Connecting siren MS-620SI (accessory part)
➤ Connect the yellow cable and the green/yellow cable to siren MS-620SI
in accordance with fig. b, page 7.
➤ Program software function 13 to "Alarm output".
➤ Program software function 9 to "Siren".
Connecting the vehicle horn
➤ Connect the yellow cable and the green/yellow cable to the vehicle horn
in accordance with fig. c, page 7.
➤ Program software function 13 to "Alarm output".
➤ Program software function 9 to "Horn".
NOTICE!
A
When connecting the vehicle horn, an operating current relay with
a recovery diode must be used which has a rating of at least 20 A.
Free slot (P6)
Not assigned.
Orange (P7)
➤ Connect this cable to a connection which is switched by the ignition
(terminal 15).
Grey (P8)
➤ Connect this cable to the bonnet contact switch (fig. a 8, page 6).
The factory setting allows for a switch which is closed when the bonnet is
open.
In case an original switch is to be used which is open when the bonnet is
open, this can be programmed in the control unit, see chapter "Function
15 (Bonnet contact input)" on page 84.
Blue (P9)
This is the signal cable for the ultrasonic module. It ends in the 3-pole
compact plug (fig. a 15, page 6).
Green (P10)
See P5.
Connecting the power to MagicSafe
73

Advertisement

Table of Contents
loading

Table of Contents