Upgrading Storeonce Software; Running A System Self Test - HP HPE StoreOnce 3100 Series Maintenance And Service Manual

Table of Contents

Advertisement

5.
After the firmware has updated, HPE recommends a cold reboot as follows:
Power down the node(s) using the StoreOnce CLI command:
system shutdown
After the system has completely shut down, wait at least one minute before powering
on using the Power On button on the server(s).
NOTE:
has been updated. For other components, it is acceptable to reboot the system using the
StoreOnce CLI command:
system reboot

Upgrading StoreOnce software

To establish which StoreOnce software version is installed, click on StoreOnce in the Navigator
and look at the Software Revision under System Information.
Check HPE Support to find out if a later software release is available at
softwaredepot. If it is, download the software release and follow the instructions in the
accompanying Release Notes to install the software.

Running a system self test

The StoreOnce CLI command, system confidencecheck, runs a self-test on the system and
produces a report of any problems. It is good practice to run this command before and after
maintenance activities. Refer to the HPE StoreOnce System CLI Reference Guide for more
information about using this command.
system/confidencechecker# runtest all
Confidence checks running. Checks will take maximum of 60 seconds. Please wait...
###############################################################################
#
# CONFIDENCE REPORT
#
###############################################################################
Report Date:
Product ID:
Cluster S/N:
Version:
Test Type:
### FILE SYSTEM REPORT ########################################################
File System Check:
[RESULT]
PASSED
### INTERNAL NETWORK REPORT ###################################################
Internal Network Check is supported only on HP StoreOnce multinode products.
### EXTERNAL NETWORK REPORT ###################################################
External Network Check:
[RESULT]
PASSED
### SAS CONFIGURATION REPORT ##################################################
Sas Configuration Check is supported only on HP StoreOnce multinode, 5500 and 4900 backup products.
### NOTE ######################################################################
For any warning or error messages in this report, please consult the troubleshooting
section in the customer user guide and follow the steps to perform corrective action.
32
Power on/off, firmware upgrades and other processes
A cold reboot is required if the network card or storage controller card firmware
Wed Nov 18 11:55:40 UTC 2015
HPE StoreOnce 3540 System
XXXXXNNNNNNXX
3.14.0-1539.3
all
www.hpe.com/support/
#
#
#