Main Functions
1.6

Night Set Mode

When the OFF timer is set, the Night Set circuit automatically activates.
The Night Set circuit maintains the airflow setting made by users.
The Night Set
The Night Set circuit continues heating or cooling the room at the set temperature for the first
Circuit
one hour, then automatically lowers the temperature setting slightly in the case of cooling, or
raises it slightly in the case of heating, for economical operations. This prevents excessive
heating in winter and excessive cooling in summer to ensure comfortable sleeping conditions,
and also conserves electricity.
Cooling Operation
Heating Operation
40
Si04-306
Function and Control