Daikin FTKS50BVMA Service Manual page 30

Hide thumbs Also See for FTKS50BVMA:
Table of Contents

Advertisement

Si04-306
Indoor Units
Model
Outdoor Units
Capacity
Rated
Moisture Removal
Running Current (Rated)
Power Consumption
Rated
Power Factor
COP
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Indoor Unit
Front Panel Color
Air Flow Rate m³/min
(cfm)
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/L
Sound
Sound Power H
Outdoor Unit
Casing Color
Type
Compressor
Model
Motor Output
Model
Refrigerant
Oil
Charge
Model
Refrigerant
Charge
m³/min
Air Flow Rate
(H/L)
cfm
Type
Fan
Motor Output
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Starting Current
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H
Sound
Sound Power H
Drawing No.
Notes:
Outdoor ; 35°CDB/24°CWB
Specifications
Cooling
kW
5.0
Btu/h
17,070
kcal/h
4,300
L/h
2.9
A
7.3
W
1,660
%
98.9
W/W
3.01
mm
mm
mm
Both Liquid and Gas Pipes
H
11.5 (406)
M
9.8 (346)
L
8.3 (293)
W
Steps
5 Steps and Auto
Right, Left, Horizontal and Downward
Removable / Washable / Mildew Proof
A
0.18
W
40
%
96.6
Microcomputer Control
mm
mm
kg
kg
dBA
44/35
dBA
63
Hermetically Sealed Swing Type
W
L
kg
47.7/44.1
1,684/1,557
W
A
7.12
W
1,620
%
98.9
A
mm
mm
kg
kg
dBA
47
dBA
63
MAX. interunit piping length: 30m
MIN. interunit piping length: 1.5m
MAX. interunit height difference: 20m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27°CDB/19°CWB
Outdoor ; 7°CDB/6°CWB
FTYS50BVMB
RYS50BVMB
Heating
5.8
19,800
4,990
7.5
1,700
98.6
3.41
φ
6.4
φ
12.7
φ
18.0
FTYS50BVMB
White
12.2 (431)
10.5 (371)
8.8 (311)
Cross Flow Fan
40
0.18
40
96.6
290×795×230
280×840×338
9
13
42/—
60
RYS50BVMB
Ivory White
2YC32HXD
1,500
FVC50K
0.65
R410A
1.20
44.1/44.1
1,557/1,557
Propeller
53
7.32
1,660
98.6
7.5
735×825×300
784×960×390
49
53
48
64
3D040784A
Heating
Piping Length
Indoor ; 20°CDB
FTYS60BVMB
RYS60BVMB
Cooling
6.0
20,480
5,160
3.9
9.3
2,120
99.1
2.83
φ
6.4
φ
12.7
φ
18.0
Both Liquid and Gas Pipes
FTYS60BVMB
White
16.4 (579)
13.9 (491)
11.6 (409)
Cross Flow Fan
43
5 Steps and Auto
Right, Left, Horizontal and Downward
Removable / Washable / Mildew Proof
0.18
40
96.6
Microcomputer Control
290×1,050×230
337×1,147×366
12
17
45/36
63
RYS60BVMB
Ivory White
Hermetically Sealed Swing Type
2YC32HXD
1,500
FVC50K
0.65
R410A
1.70
47.6/44.1
1,680/1,557
Propeller
53
9.12
2,080
99.2
9.3
735×825×300
784×960×390
53
57
49
64
3D040785
7.5m
Specifications
230V, 50Hz
Heating
7.0
23,900
6,020
9.2
2,090
98.8
3.35
17.5 (618)
15.2 (537)
12.8 (452)
0.18
40
96.6
44/—
62
45.5/45.5
1,606/1,606
9.02
2,050
98.8
49
64
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents