Piping Diagrams
1.2

Outdoor Units

1.2.1 Cooling Only
RKS50BVMA, RKS50BVMB, RS50BVMB
OUTDOOR UNIT
7.9CuT
12.7CuT
7.9CuT
7.9CuT
HEAT EXCHANGER
THERMISTOR
PROPELLER FAN
7.9CuT
DISCHARGE PIPE
THERMISTOR
RKS 60/71 BVMA, RKS 60/71 BVMB, RS60BVMB
OUTDOOR UNIT
7.9CuT
7.9CuT
7.9CuT
12.7CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
HEAT
EXCHANGER
THERMISTOR
PROPELLER FAN
7.9CuT
DISCHARGE PIPE
THERMISTOR
186
HEAT EXCHANGER
OUTDOOR AIR TEMPERATURE
THERMISTOR
7.9CuT
7.9CuT
7.9CuT
M
12.7CuT
ACCUMLATOR
COMPRESSOR
HEAT EXCHANGER
OUTDOOR AIR TEMPERATURE
THERMISTOR
7.9CuT
7.9CuT
7.9CuT
7.9CuT
M
12.7CuT
ACCUMLATOR
COMPRESSOR
CAPILLARY TUBE 1
MUFFLER
WITH
FILTER
6.4CuT
CAPILLARY TUBE 2
CAPILLARY TUBE 3
12.7CuT
12.7CuT
WITH SERVICE PORT
CAPILLARY TUBE 1
MUFFLER
WITH
FILTER
CAPILLARY TUBE 2
6.4CuT
CAPILLARY TUBE 3
CAPILLARY TUBE 4
12.7CuT
12.7CuT
REFRIGERANT FLOW
COOLING
MOTOR OPERATED
VALVE
FIELD PIPING
( 6.4CuT )
6.4CuT
LIQUID
STOP VALVE
FIELD PIPING
( 12.7CuT )
GAS STOP VALVE
REFRIGERANT FLOW
COOLING
MODEL
RKS60 , RS60
RKS71
MOTOR OPERATED
VALVE
FIELD PIPING
( 6.4 CuT )
6.4CuT
LIQUID
STOP VALVE
FIELD PIPING
( AA CuT )
GAS STOP VALVE
WITH SERVICE PORT
Si04-306
3D037835A
AA
12.7
15.9
3D037836A