Data editing-related errors
Code
The enlargement ratio setting caused the sewing data to extend outside the sewing area.
E500
Set the enlargement ratio again.
Press the RESET key to clear the error.
The enlargement ratio caused the data pitch to exceed the maximum pitch of 12.7 mm.
E502
Press the RESET key to clear the error. Set the enlargement ratio again.
Error in sewing data.
E510
Press the RESET key to clear the error.
If an error occurs while reading or revising the sewing data, revise the data.
No end code has been input into pattern data.
E511
Press the RESET key to clear the error.
Number of stitches exceeds allowed maximum.
E512
Press the RESET key to clear the error.
Extended option output number already exists.
E520
Change the extended option output number.
If not using the extended option output, initialize the data to clear the extended option output data.
Memory switch file cannot be read correctly.
E581
The model for the data which was read does not match the model being written to.
Press the RESET key to clear the error. Read data for the same sewing machine model.
Memory switch versions do not match.
E582
Press the RESET key to clear the error. Read data for the same version.
User program versions do not match.
E583
Press the RESET key to clear the error. Read data for the same version.
Device-related errors
Code
Upper thread breakage occurred. Thread the upper thread. Re-sewing is then possible.
E600
Turn off the power, and then check that connectors P9 and P36 on the main P.C. board are properly connected.
Problem with the lower thread detector.
E670
Turn off the power, and then check the lower thread detector.
Cause of error and remedy
Cause of error and remedy
BAS-311HN, BAS-326H
8. LIST OF ERROR CODES