7. STANDARD ADJUSTMENTS
3
Memorizing the neutral position
4
Memorizing the maximum backward position
5
Completion of setting
6
Turn off the power.
50
BAS-311HN, BAS-326H
With your foot released from the foot switch,
wait until the depression voltage value
stabilizes and then touch the OK key.
With the foot switch depressed all the way
backward, wait until the depression voltage
value stabilizes and then touch the OK key.
A finished message will be displayed.
NOTE:
If the foot switch operation is not carried out
correctly, an error will be displayed. If this
happens, repeat the operation from step 2.