Brother bas-311hn Instruction Manual page 55

Table of Contents

Advertisement

<Stepping clamp connecting rod position adjustment>
3138B
1. Loosen the screw (1), and then open the cover (2).
2. Loosen the nut (3), and then adjust the position of the stepping clamp connecting rod (4).
• When the stepping clamp connecting rod (4) is raised, the intermittent presser foot stroke will increase.
• When the stepping clamp connecting rod (4) is lowered, the intermittent presser foot stroke will decrease.
Next, adjust the needle bar and intermittent presser foot timing.
3. Turn the pulley in the direction of the arrow to raise the needle bar from the lowest position until the lowest reference line
on the needle bar (reference line B) is aligned with the lower edge of the needle bar bush (5).
(If using a DP x 5 needle, align with the second reference line from the top (reference line b).)
4. Open the top cover and loosen the two set screws (6).
5. Align the index marks of the stepping clamp cam (7) and the stepping clamp connecting rod (4), and then tighten the two
set screws (6).
Check the following after changing the intermittent presser foot stroke.
1. With the intermittent presser foot (1) lowered, turn the pulley in the direction of the arrow to move the intermittent
presser foot (1) to its lowest position.
2. Check that the presser foot (1) does not touch the needle plate and that the presser bar clamp (2) does not touch the
presser bar bush (3).
<If they are touching>
Remove the motor cover (4).
Loosen the nut (5), and turn the bolt (6) until it is pressing against the intermittent drive lever (7), and then adjust until
the two points mentioned above are not touching.
Needle plate
BAS-311HN, BAS-326H
7. STANDARD ADJUSTMENTS
Index mark
3139B
5014Q
5015Q
3511B
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bas326h

Table of Contents