Cooling Capacity Df120 (10 Ton) Unit - York Predator DF 078 Technical Manual

Mid efficiency single package air conditioners and single package gas/electric units
Table of Contents

Advertisement

246699-YTG-D-1208
TABLE 8: COOLING CAPACITY DF120 (10 TON) UNIT
Return Air
Gross
Input
WB
*
CFM
Cap.
Power
(°F)
(MBH)
72
119.5
67
116.6
3000
62
112.6
57
109.2
72
122.4
67
119.4
3500
62
115.3
57
111.8
72
125.2
67
122.1
4000
62
118.0
57
114.4
72
125.5
67
122.4
4500
62
118.3
57
114.7
72
125.8
67
122.7
5000
62
118.5
57
115.0
Outdoor Ambient Temperature
72
113.3
10.02
67
106.2
3000
62
103.6
57
103.3
72
117.0
10.10
67
109.7
3500
62
107.0
57
106.7
72
120.7
10.17
67
113.2
4000
62
110.4
57
110.1
72
121.9
10.22
67
114.3
10.04
4500
62
111.5
57
111.2
72
123.1
10.27
67
115.4
10.09
5000
62
112.6
57
112.3
Outdoor Ambient Temperature
72
101.1
67
90.7
3000
62
92.0
57
91.8
72
106.8
67
95.9
3500
62
97.2
57
97.0
72
112.6
67
101.1
4000
62
102.5
57
102.2
72
114.0
67
102.4
4500
62
103.8
57
103.5
72
115.4
67
103.7
5000
62
105.1
57
104.8
16
Outdoor Ambient Temperature 85°F
Gross Sensible Capacity (MBH)
Return Air Dry Bulb (°F)
(kW)
86
83
80
77
8.47
73.6 65.1 56.5 48.0 39.4
8.49
94.8 86.2 77.7 69.1 60.5 52.0 43.4
8.43
112. 106. 98.3 89.8 81.2 72.7 64.1
8.41
109. 109. 101. 93.0 84.4 75.9 67.3
8.52
80.0 69.9 59.8 49.7 39.6
8.54
102. 92.3 82.2 72.1 62.0 51.9 41.7
8.47
115.
112. 104. 94.0 83.9 73.8 63.6
8.45
111.8 111.8 107. 97.3 87.2 77.1 67.0
8.56
86.4 74.8 63.1 51.4 39.8
8.59
110. 98.4 86.7 75.0 63.4 51.7 40.1
8.52
118.
118. 109. 98.2 86.5 74.8 63.2
8.50
114.
114.
113. 101. 90.0 78.4 66.7
8.56
91.5 78.2 64.9 51.6 38.3
8.59
115. 102. 89.2 75.9 62.6 49.3 36.1
8.52
118.
118.
113. 99.7 86.4 73.1 59.8
8.50
114.
114.
114. 100. 87.6 74.3 61.0
8.56
96.5 81.6 66.7 51.8 36.9
8.59
121. 106. 91.7 76.8 61.9 47.0 32.1
8.52
118.
118.
116. 101. 86.3 71.4 56.5
8.50
115.
115.
115. 100. 85.2 70.3 55.3
71.2 62.6 54.1 45.5 37.0
9.85
91.5 82.9 74.4 65.8 57.3 48.7 40.2
9.74
103. 97.2 88.7 80.1 71.6 63.0 54.4
9.75
102. 93.9 85.3 76.8 68.2 59.7 51.1
78.6 68.5 58.4 48.2 38.1
9.92
100. 90.4 80.3 70.2 60.1 50.0 39.9
9.81
106. 103. 95.6 85.5 75.4 65.3 55.2
9.82
106. 102. 92.1 82.0 71.9 61.8 51.6
86.0 74.3 62.6 51.0 39.3
9.99
108. 97.9 86.2 74.5 62.9 51.2 39.5
9.87
110.
110. 102. 90.9 79.3 67.6 55.9
9.89
110.
110. 98.8 87.2 75.5 63.8 52.2
92.5 79.2 65.9 52.6 39.3
112. 103. 90.7 77.4 64.1 50.8 37.5
9.93
111.5 111.5 107. 94.0 80.7 67.4 54.1
9.94
111.2 111.2 103. 90.6 77.3 64.1 50.8
99.0 84.1 69.2 54.3 39.3
115. 109. 95.2 80.3 65.3 50.4 35.5
9.98
112.
112.
112. 97.1 82.2 67.3 52.4
9.99
112.
112. 109. 94.1 79.2 64.3 49.4
11.4
67.0 58.5 49.9 41.3 32.8
11.0
85.9 77.3 68.8 60.2 51.7 43.1 34.6
11.0
91.4 80.5 72.0 63.4 54.9 46.3 37.8
10.9
90.0 81.5 72.9 64.4 55.8 47.3 38.7
11.6
75.8 65.7 55.6 45.4 35.3
11.2
95.7 86.7 76.6 66.4 56.3 46.2 36.1
11.2
96.9 91.5 80.4 70.3 60.2 50.1 40.0
11.1
96.1 91.7 81.3 71.2 61.1 51.0 40.9
11.8
84.5 72.9 61.2 49.5 37.9
11.3
101. 96.0 84.3 72.7 61.0 49.4 37.7
11.3
102. 102. 88.8 77.1 65.5 53.8 42.1
11.2
102. 101. 89.7 78.1 66.4 54.8 43.1
11.8
92.2 78.9 65.6 52.4 39.1
11.4
102. 102. 90.5 77.2 63.9 50.6 37.3
11.4
103. 103. 96.0 82.7 69.4 56.1 42.9
11.3
103. 103. 96.4 83.1 69.8 56.5 43.2
11.9
99.9 85.0 70.1 55.2 40.3
11.5
103. 103. 96.6 81.7 66.8 51.8 36.9
11.5
105. 105. 103. 88.3 73.4 58.5 43.6
11.4
104. 104. 103. 88.1 73.2 58.2 43.3
*
Gross
Input
*
Cap.
Power
(MBH)
(kW)
74
71
68
-
-
119.3
9.31
114.0
9.25
109.4
9.11
109.1
9.16
-
-
122.0
9.34
116.6
9.28
111.9
9.13
111.6
9.19
-
-
124.7
9.37
119.2
9.31
114.4
9.16
114.1
9.22
-
-
125.8
9.41
120.2
9.35
115.4
9.20
115.1
9.25
-
-
126.9
9.45
121.3
9.38
116.4
9.24
116.0
9.29
105°F
Outdoor Ambient Temperature
-
-
107.2
10.74
98.5
10.44
97.8
10.37
97.6
10.34
-
-
111.9
10.85
102.8
10.55
102.1
10.48
101.9
10.45
-
-
116.6
10.96
107.1
10.66
106.4
10.59
106.2
10.56
-
-
117.9
11.03
108.3
10.73
107.7
10.65
107.4
10.62
-
-
119.3
11.10
109.6
10.79
108.9
10.72
108.6
10.68
125°F
-
-
* The capacities are gross ratings. For net capacity,
deduct indoor blower motor, MBH=3.415 x kW.
Refer to the appropriate Blower Performance table
for the kW of the supply air blower motor.
-
-
Input power includes the condenser and compressor
motors but not the indoor blower motor.
-
-
-
-
-
-
Outdoor Ambient Temperature 95°F
Gross Sensible Capacity (MBH)
Return Air Dry Bulb (°F)
86
83
80
77
73.2 64.7 56.1 47.6 39.0
94.3 85.7 77.2 68.6 60.1 51.5 43.0
109. 105. 97.0 88.4 79.9 71.3 62.8
108. 100. 91.6 83.0 74.4 65.9 57.3
80.0 69.9 59.8 49.6 39.5
102. 92.3 82.2 72.1 61.9 51.8 41.7
111.9 110. 103. 93.1 83.0 72.9 62.8
111.4 107. 97.5 87.3 77.2 67.1 57.0
86.7 75.0 63.4 51.7 40.0
110. 98.8 87.1 75.5 63.8 52.1 40.5
114.
114. 109. 97.8 86.2 74.5 62.8
114.
114. 103. 91.7 80.0 68.4 56.7
92.6 79.3 66.0 52.8 39.5
115. 104. 90.8 77.5 64.2 50.9 37.7
115.
115.
112. 99.7 86.4 73.1 59.8
115.
115. 107. 94.4 81.1 67.8 54.6
98.5 83.6 68.7 53.8 38.9
121. 109. 94.5 79.6 64.6 49.7 34.8
116.
116.
116. 101. 86.6 71.7 56.8
116.
116.
112. 97.1 82.2 67.3 52.4
69.1 60.5 52.0 43.4 34.9
88.7 80.1 71.6 63.0 54.5 45.9 37.4
97.4 88.9 80.3 71.8 63.2 54.7 46.1
96.2 87.7 79.1 70.6 62.0 53.5 44.9
77.2 67.1 57.0 46.8 36.7
97.9 88.5 78.4 68.3 58.2 48.1 38.0
101. 97.7 88.0 77.9 67.8 57.7 47.6
101. 96.8 86.7 76.6 66.5 56.4 46.3
85.3 73.6 61.9 50.3 38.6
107. 96.9 85.3 73.6 61.9 50.3 38.6
106. 106. 95.7 84.0 72.4 60.7 49.0
106. 105. 94.3 82.6 71.0 59.3 47.6
92.3 79.1 65.8 52.5 39.2
108. 103. 90.6 77.3 64.0 50.7 37.4
107. 107. 101. 88.4 75.1 61.8 48.5
107. 107. 100. 86.9 73.6 60.3 47.0
99.4 84.5 69.6 54.7 39.8
109. 109. 95.9 81.0 66.1 51.1 36.2
108. 108. 107. 92.7 77.8 62.9 48.0
108. 108. 106. 91.1 76.2 61.3 46.4
Johnson Controls Unitary Products
*
74
71
68
-
-
-
-
-
-
-
-
-
-
115°F
-
-
-
-
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Predator df 090Predator df 102Predator df 120

Table of Contents