Adjustment
11
Needle height (preliminary adjustment)
.04.02
Requirement
With the needle bar at b.d.c. the clearance between needle bar and needle plate must be
23 mm (on the PFAFF 333-712/02) and 15 mm (on the PFAFF 333-712/03.
2
1
1
Fig. 11 - 02
● Position the height of needle bar 1 (screws 2) according to Requirement, but do not
turn it.
11 - 3